AbstractIn this paper, an LNG BOG re-liquefaction system operating according to the Claude refrigeration cycle using oxygen as refrigerant is analysed. It includes a comprehensive exergy analysis of a BOG reliquefaction system installed onboard an LNG carrier. Commonly operating data have been used to carry out a thermodynamic analysis of the system. The system is basically made of two parts: Oxygen cycle and LNG BOG cycle.
Oxygen, Thermodynamic, BOG, LNG, Re-liquefaction
Oxygen, Thermodynamic, BOG, LNG, Re-liquefaction
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 11 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |