Silicon photomultiplier devices (SiPM) were investigated as a possible front-end detector system for the electromagnetic barrel calorimeter of the GlueX Project at Jefferson Laboratory, USA, and compared against a traditional 2 in vacuum photomultiplier tube. The SiPM has gain and timing resolution comparable to that of a PMT, requires a simple electronic circuit and is not sensitive to magnetic fields. These attributes allow us to conclude that it is feasible to use the SiPM as a front-end detector for this calorimeter.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 70 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |