pmid: 26691047
We report the results of a comparative study at a single center on 214 eyes of 109 pediatric patients in whom IOP was measured using the Icare rebound tonometer and Goldmann applanation tonometry. Measurements from the two modalities demonstrated a correlation coefficient of 0.83 (P < 0.001), with Icare measuring on average 1.38 mm Hg higher. Compared to Goldmann, the Icare was more easily tolerated in the children studied. In 37 eyes that tolerated pachymetry, central corneal thickness was positively correlated with Icare measurements.
Male, Tonometry, Ocular, Adolescent, Corneal Pachymetry, Humans, Female, Prospective Studies, Child, Intraocular Pressure
Male, Tonometry, Ocular, Adolescent, Corneal Pachymetry, Humans, Female, Prospective Studies, Child, Intraocular Pressure
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 22 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |