Long QT syndrome (LQTS) is characterized by reduced penetrance and variable QT prolongation over time, resulting in an estimate of 25% carriers of a pathogenic mutation with a normal corrected QT (QTc) interval on the resting electrocardiogram (ECG).The purpose of this study was to test the hypothesis that an individualized corrected QT interval derived from 24-hour Holter data more accurately predicts carriage of a pathogenic LQTS mutation than did QT derived from a standard 12-lead ECG and corrected using the Bazett formula (QTc interval).Carriers of a pathogenic LQTS mutation and their genotype-negative family members who had both resting ECG and Holter recordings available were included. Automated and manual measurements of QTc were performed. QTi was derived from 24-hour Holter recordings and defined as the QT value at the intersection of an RR interval of 1000 ms, with the linear regression line fitted through QT-RR data points of each individual patient.In total, 69 patients with LQTS (23 long QT type 1, 39 long QT type 2, and 7 long QT type 3) and 55 controls were selected. Demographic characteristics were comparable. A comparison of the receiver operating characteristic curves indicates that the test added diagnostic value compared to manual measurement (P = .02) or automated measurement (P = .005). The diagnostic accuracy of manually measured QTc using conventional cutoff criteria was 72%, while it was 92% using a sex-independent QTi cutoff of 445 ms. This was caused by a 39% increase in sensitivity without compromising the specificity.QTi derived from Holter recordings is superior to conventional QTc measured from a standard 12-lead ECG in predicting the mutation carrier state in families with LQTS.
Adult, Male, Observer Variation, Patient-Specific Modeling, Genotype, Reproducibility of Results, Middle Aged, Quality Improvement, Long QT Syndrome, ROC Curve, Dimensional Measurement Accuracy, Heart Rate, Mutation, Electrocardiography, Ambulatory, Humans, Female, Human medicine
Adult, Male, Observer Variation, Patient-Specific Modeling, Genotype, Reproducibility of Results, Middle Aged, Quality Improvement, Long QT Syndrome, ROC Curve, Dimensional Measurement Accuracy, Heart Rate, Mutation, Electrocardiography, Ambulatory, Humans, Female, Human medicine
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 18 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |