Abstract Static and instantaneous behaviour of connections between steel and concrete is investigated in the context of composite beam bridges with high strength concrete. Push-out tests were performed under a range of conditions and analysed by means of a 3D-FE model. Experimental results show that the average ultimate shear stress is about 5.5 MPa and the response mainly depends on the behaviour of the concrete under a 2D state of stress. Moreover, bonded connections exhibit a very high stiffness and almost the same strength as mechanical connectors. Furthermore beam simulations show that bonded connections could be modelled as perfectly bonded beams with a good accuracy. The risk of cracking in the concrete slab is also significantly reduced which may increase the durability of bonded steel–concrete composite structures compared with those equipped with mechanical connectors.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 49 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |