Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Intensive Care Medic...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Intensive Care Medicine
Article . 1997 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
versions View all 2 versions
addClaim

PEEP-induced tricuspid regurgitation

Authors: H, Artucio; J, Hurtado; L, Zimet; J, de Paula; M, Beron;

PEEP-induced tricuspid regurgitation

Abstract

To determine the presence of tricuspid regurgitation (TR) in patients affected by acute lung injury (ALI) and the adult respiratory distress syndrome (ARDS) during mechanical ventilation with positive end-expiratory pressure (PEEP).A prospective clinical study.10-bed general intensive care unit in a University Hospital.7 consecutive patients an age 44.7 +/- 8.6 years with a diagnosis of ALI or ARDS were studied. All were on mechanical ventilation with PEEP.PEEP was increased in steps of 5 cm H2O until the appearance of TR or up to a limit of 20 cm H2O.Right atrial pressure, pulmonary artery pressure, and wedge pressure were measured and cardiac output was determined by thermodilution. TR was graded from 0 to 3. Standard 2D echocardiographic and pulsed-wave images were obtained at each level of PEEP. PEEP was increased from 4 +/- 3 to 17 +/- 2 cm H2O. Mean PAP increased from 27.7 +/- 2.9 to 36.7 +/- 3.5 mm Hg (p < 0.02) when PEEP was increased. Five patients had competent valves and two had mild TR at baseline. In six out of the seven, TR either developed or increased when PEEP was increased.Our study demonstrated the development of TR after the use of PEEP in patients with ALI and ARDS as a consequence of pulmonary hypertension and right ventricular overloading. Since TR may randomly affect cardiac output values and derived parameters, the assessment of cardiac performance by some techniques such as thermodilution should be used with caution.

Related Organizations
Keywords

Adult, Echocardiography, Doppler, Pulsed, Male, Respiratory Distress Syndrome, Hypertension, Pulmonary, Ventricular Dysfunction, Right, Thermodilution, Cardiac Output, Low, Hemodynamics, Middle Aged, Tricuspid Valve Insufficiency, Positive-Pressure Respiration, Linear Models, Humans, Female, Prospective Studies, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    26
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
26
Top 10%
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!