doi: 10.1007/bf02418632
Investigation of a pulsed pneumatic transportation system for spent fuel is briefly described. Testing parameters for air transport included nozzle optimization and transportation range. The range of particles (30 to 40 mm metal chunks) was determined as a function of the nozzle diameter. A 35 mm diameter was determined to be optimal for the receiver volume and initial gas pressure. Experimental results showed that as receiver volume increases, the transportation range increases linearly until a critical volume is reached; at that point, range becomes constant. As initial gas pressure increases, the transportation range curve is displaced upwards. The system gave stable movement of the metal chunks, eliminating plugs in the standard operating regime. 5 refs., 3 figs.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |