doi: 10.1007/bf01577453
An experimental study on heat transfer performance of a gravity-assisted heat pipe is described. Dowtherm A has been used as working fluid. The effect of fill ratio, inclination angle, heat length ratio, and thermal resistance on the rate of heat flow were investigated. Finding a dependence of the maximum rate of heat flow on the first two parameters, a corresponding numerical correlation has been formulated. The force of viscosity shear and the force of momentum transfer during the condensation have been accounted for, and, with a theoretical analysis and a numerical solution, a mean heat transfer coefficient in the condensation section is given.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |