The main objectives of the present paper are: (i) to identify the areas in Kalyani region, Kolkata, i.e. AIIMS Kolkata campus in which soil formations are prone to amplifying ground motions and (ii) to analytically evaluate amplification ratio using computer program for earthquake site response analysis. Peak ground acceleration at different depth is calculated for all the selected six sites with the help of soil profile. For this purpose, one-dimensional linear ground response analysis is done by the help of DEEPSOIL V-7.0 computer program. It can be observed that from the results peak ground acceleration of different site is varying from 0.159 to 0.190 g and the soil amplification value is ranging from 0.996 to 1.190 for peak ground acceleration of 0.16 g.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |