Auxiliary systems, such as instrument air, DC power and cooling water play an important part in keeping a nuclear power plant operating. This paper looks at failures which have occurred in these systems. A new technique for analyzing plant auxiliary systems to detect potential interactions between the auxiliary systems and other plant systems is presented. This Commonality Failure Analysis Technique is applied to the analysis of a typical auxiliary system.