doi: 10.1002/ccd.24516
pmid: 22707435
Treatment options for re‐stenotic aortic valve prosthesis implanted by transcatheter technique have not been evaluated systematically. We describe the case of a 75‐year‐old dialysis patient who was treated by transcatheter aortic valve implantation 3.5 years ago and now presented with severe stenosis of the percutaneous heart valve. The patient was initially treated with a trans‐apical implantation of an Edwards Sapien 26 mm balloon expandable valve. The patient remained asymptomatic for 3 years when he presented with increasing shortness of breath and significant calcification of the valve prosthesis on transesophageal echocardiography. Valve‐in‐valve percutaneous heart valve implantation using a 26‐mm CoreValve prosthesis was performed under local anesthesia. The prosthesis was implanted without prior valvuloplasty. Pacing with a frequency of 140/min was applied during placement of the valve prosthesis. Positioning was done with great care using only fluoroscopic guidance with the aim to have the ventricular strut end of the CoreValve prosthesis 5 mm higher than the ventricular strut end of the Edwards Sapien prosthesis. After placement of the CoreValve prosthesis within the Edwards Sapien valve additional valvuloplasty with rapid pacing was performed in order to further expand the CoreValve prosthesis. The final result was associated with a remaining mean gradient of 5 mm Hg and no aortic regurgitation. In conclusion, implantation of a CoreValve prosthesis for treatment of a restenotic Edwards Sapien prosthesis is feasible and is associated with a good functional result. © 2012 Wiley Periodicals, Inc.
Balloon Valvuloplasty, Heart Valve Prosthesis Implantation, Cardiac Catheterization, Cardiac Pacing, Artificial, Aortic Valve Stenosis, Prosthesis Design, Radiography, Interventional, Prosthesis Failure, Treatment Outcome, Recurrence, Heart Valve Prosthesis, Humans, Echocardiography, Transesophageal, Aged
Balloon Valvuloplasty, Heart Valve Prosthesis Implantation, Cardiac Catheterization, Cardiac Pacing, Artificial, Aortic Valve Stenosis, Prosthesis Design, Radiography, Interventional, Prosthesis Failure, Treatment Outcome, Recurrence, Heart Valve Prosthesis, Humans, Echocardiography, Transesophageal, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 10 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |