doi: 10.2166/wst.2021.197
pmid: 34185701
Abstract Reliance on biochemical oxygen demand (BOD5) as an indicator of wastewater quality has hindered the development of efficient process control due to the associated uncertainty and lag-times. Surrogate measurements have been proposed, with fluorescence spectroscopy a promising technique. Yet, assessment of in-situ fluorescence sensors across multiple wastewater treatment plants (WwTPs), and at different treatment stages, is limited. In this study a multi-parameter sonde (two fluorescence peaks, turbidity, temperature and electrical conductivity) was used to provide a BOD5 surrogate measurement. The sonde was deployed at three WwTPs, on post primary settlement tanks (PST) and final effluent (FE). Triplicate laboratory measurements of BOD5, from independent laboratories were used to calibrate the sensor, with high variability apparent for FE samples. Site and process specific sensor calibrations yielded the best results (R2cv = 0.76–0.86; 10-fold cross-validation) and mean BOD5 of the three laboratory measurements improved FE calibration. When combining PST sites a reasonable calibration was still achieved (R2cv = 0.67) suggesting transfer of sensors between WwTPs may be possible. This study highlights the potential to use online optical sensors as robust BOD5 surrogates in WwTPs. However, careful calibration (i.e. replicated BOD5 measurements) is required for FE as laboratory measurements can be associated with high uncertainty.
post primary settlement, Wastewater, final effluent, Environmental technology. Sanitary engineering, turbidity, Water Purification, Spectrometry, Fluorescence, high frequency monitoring, Calibration, humic-like fluorescence, sensor calibration, tryptophan-like fluorescence, TD1-1066
post primary settlement, Wastewater, final effluent, Environmental technology. Sanitary engineering, turbidity, Water Purification, Spectrometry, Fluorescence, high frequency monitoring, Calibration, humic-like fluorescence, sensor calibration, tryptophan-like fluorescence, TD1-1066
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 18 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |