
Purpose. The complex approach to calculating thunderstorm overvoltage on substation equipment is considered when lightning strikes in a lightning rod. Methodology. The conditions of safe passage of lightning current through a lightning arrester are formulated. Results. It is shown that the calculation of the permissible length of air insulating gaps in the substation is based on the breakdown of the air tension, which is assumed to be 500 kV/m. This leads to an error in calculating the length of the air gap and, as a consequence, the probability of its breakdown, the value of which is used to calculate the indicator of the lightning resistance of the substation. A technique is proposed for calculating the permissible voltage on the transformer case when a lightning strike strikes the lightning receptacle of the transformer portal. On the basis of the nonlinear pulsed electric strength of the ground, the specified minimum permissible ground distance between the grounding rod of the lightning rod and the nearest point of the protected device is obtained. Originality. Refined calculation of the length of the minimum breakdown gap in the air and in the ground. Practical value. The proposed approach makes it possible to calculate thunderstorm overvoltage on substation equipment.
воздушный промежуток, substation, lightning arrester, air gap, transformer case, электрическое поле, грозовые перенапряжения, корпус трансформатора, импульсная электрическая прочность, electric field, TK1-9971, молниеотвод, 621.316.93, permissible voltage, pulsed electric strength, подстанция, volt-second characteristic, вольт-секундная характеристика, допустимое напряжение, insulator string, Electrical engineering. Electronics. Nuclear engineering, lightning overvoltage, гирлянда изоляторов
воздушный промежуток, substation, lightning arrester, air gap, transformer case, электрическое поле, грозовые перенапряжения, корпус трансформатора, импульсная электрическая прочность, electric field, TK1-9971, молниеотвод, 621.316.93, permissible voltage, pulsed electric strength, подстанция, volt-second characteristic, вольт-секундная характеристика, допустимое напряжение, insulator string, Electrical engineering. Electronics. Nuclear engineering, lightning overvoltage, гирлянда изоляторов
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
