Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Energy-Efficiency in...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Thermal performance of assembled systems of exterior wall using cement boards KNAUF AQUAPANEL® OUTDOOR

Authors: Tymofieiev, Mykola; Shamrina, Galina; Khokhrіakova, Daria;

Thermal performance of assembled systems of exterior wall using cement boards KNAUF AQUAPANEL® OUTDOOR

Abstract

Конструкції збірної системи з використанням цементних плит КНАУФ AQUAPANEL® Cement Board Outdoor мають очевидні переваги. Теплові мости, що створюються інтенсивним використанням стали в каркасі системи, можуть значно знижувати теплотехнічні характеристики конструкції.Дослідження було спрямоване на визначення області раціонального застосування збірних систем в якості зовнішніх огороджень будівель в кліматичних умовах України. Застосовувався метод чисельного моделювання двомірних температурних полів та теплових потоків із використанням програми THERM 7.5.За конструктивним рішенням було обрано чотири збірних системи з використанням цементної плити КНАУФ AQUAPANEL® Cement Board Outdoor з однорядним та дворядним розташуванням металевих суцільних стійкових профілів компанії "STEELCO" з висотою перетину 100, 150 і 200 мм і шагом 400 мм. Розрахунки приведеного опору теплопередачі виконувались за умов дотримання мінімальних вимог згідно ДСТУ В.2.6-189:2013, що встановлюються при визначенні необхідної товщини теплоізоляційного шару в конструкції. Враховувався термічний вплив теплопровідних включень, що є характерними для обраних конструкцій: - металеві стійки каркасу глухих ділянок стіни і віконні відкоси в місцях розташування світлопрозорих огороджувальних конструкцій. За результатами моделювання для кожної збірної системи і відповідних стійкових профілів були визначені лінійні коефіцієнти та приведений опір теплопередачі.За результатами розрахунків визначені варіанти збірних систем, які відповідають мінімальним вимогам. Для житлового і громадського будівництва в І температурній зоні – збірна система 2 з висотою перерізу стійкового профілю 150 та 200 мм; в ІІ температурній зоні - збірна система 2 з висотою перерізу стійкового профілю 100, 150, 200 мм та збірна система 3 з висотою перерізу стійкового профілю 200 мм.

Assembled systems using Knauf AQUAPANEL® Cement Board Outdoor have obvious advantages. Thermal bridges, which are created by intensive use of steel in the system frame, can significantly reduce the thermal performance of the structure.The research was aimed at determining the range of assembled systems application as exterior walls of buildings in Ukraine’s climatic conditions. Numerical simulations of two-dimensional temperature field and heat flow rate were applied using THERM 7.5.According to the constructive solution, four assembled systems were selected using the Knauf AQUAPANEL® Cement Board Outdoor with single-row and two-row arrangement of a solid metal stud of the STEELCO company with a depth cross-section of 100, 150 and 200 mm and 400 mm post spacing.The reduced heat transfer resistance was calculated based on the minimum requirements in accordance with GOST В.2.6-189: 2013, established when the required heat-insulating layer’s thickness of the structure is determined. The thermal effects of linear thermal bridges, characteristic for selected structures, were considered - metal studs of the wall framework and jamb wall.Based on the numerical simulations, linear thermal transmittance and reduced heat transfer resistance were determined for each assembled system and for each depth of cross-sections of the metal studs.Based on the calculations the options of assembled systems that meet the minimum requirements have been specified.For civil buildings in the I temperature zone - assembled system 2, options with a depth of cross-section of metal stud 150 and 200 mm; in the II temperature zone, there is an assembled system 2, options with a depth of cross-section of metal stud 100, 150, 200 mm and an assembled system 3, option with a depth of cross-section of metal stud 200 mm.

Keywords

Reduced heat transfer; linear thermal transmittance; thermal bridges; assembled system; AQUAPANEL® Cement Board Outdoor, Приведений опір теплопередачі; лінійний коефіцієнт теплопередачі; теплові мости; збірна система; плита AQUAPANEL® Cement Board Outdoor.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
hybrid
Related to Research communities