Purpose. The windings of power transformers have low resistance value and a most inductance, which reduces the rate of rise of current in the windings. Therefore, when the estimated amount of current is set one should make sure of the possibility of achieving it. As inductance is characterized by a short-circuit voltage, it is necessary to develop a technique for determining the maximum magnitude of the current in the windings of the transformer according to the short-circuit voltage and operating frequency. Methodology. The classical method of calculation of transient processes to determine the value of the transient current of the transformer windings to achieve purpose is used. Findings. The nature of the transient current in the windings of high-frequency transformer, which is powered by a voltage inverter is investigated and analyzed. Originality. The method for determining the maximum amount of current depending on the short-circuit voltage and frequency of the applied voltage with other set-up parameters was proposed. Practical value. The proposed method allows determining the maximum value of the current in the windings of the high-frequency transformer including its RL-parameters. This will let compare the value of a given current with possible depending on short-circuit voltage and frequency of the applied voltage. Research material may be applied for power transformers design.
однофазный мостовой инвертор напряжения; высоковольтный трансформатор; напряжение короткого замыкания; переходной процесс; постоянная времени, Transportation engineering, TA1001-1280, transient process, однофазний мостовий інвертор напруги; високовольтний трансформатор; напруга короткого замикання; перехідний процес; постійна часу, single-phase bridge voltage inverter; high voltage transformer; short-circuit voltage; transient process; time constant, short-circuit voltage, time constant, single-phase bridge voltage inverter, high voltage transformer
однофазный мостовой инвертор напряжения; высоковольтный трансформатор; напряжение короткого замыкания; переходной процесс; постоянная времени, Transportation engineering, TA1001-1280, transient process, однофазний мостовий інвертор напруги; високовольтний трансформатор; напруга короткого замикання; перехідний процес; постійна часу, single-phase bridge voltage inverter; high voltage transformer; short-circuit voltage; transient process; time constant, short-circuit voltage, time constant, single-phase bridge voltage inverter, high voltage transformer
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 3 | |
| downloads | 3 |

Views provided by UsageCounts
Downloads provided by UsageCounts