image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao American Heart Journ...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
American Heart Journal
Article . 2014 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Comparison of automated measurements of electrocardiographic intervals and durations by computer-based algorithms of digital electrocardiographs

Authors: Paul, Kligfield; Fabio, Badilini; Ian, Rowlandson; Joel, Xue; Elaine, Clark; Brian, Devine; Peter, Macfarlane; +6 Authors

Comparison of automated measurements of electrocardiographic intervals and durations by computer-based algorithms of digital electrocardiographs

Abstract

Automated measurements of electrocardiographic (ECG) intervals are widely used by clinicians for individual patient diagnosis and by investigators in population studies. We examined whether clinically significant systematic differences exist in ECG intervals measured by current generation digital electrocardiographs from different manufacturers and whether differences, if present, are dependent on the degree of abnormality of the selected ECGs.Measurements of RR interval, PR interval, QRS duration, and QT interval were made blindly by 4 major manufacturers of digital electrocardiographs used in the United States from 600 XML files of ECG tracings stored in the US FDA ECG warehouse and released for the purpose of this study by the Cardiac Safety Research Consortium. Included were 3 groups based on expected QT interval and degree of repolarization abnormality, comprising 200 ECGs each from (1) placebo or baseline study period in normal subjects during thorough QT studies, (2) peak moxifloxacin effect in otherwise normal subjects during thorough QT studies, and (3) patients with genotyped variants of congenital long QT syndrome (LQTS).Differences of means between manufacturers were generally small in the normal and moxifloxacin subjects, but in the LQTS patients, differences of means ranged from 2.0 to 14.0 ms for QRS duration and from 0.8 to 18.1 ms for the QT interval. Mean absolute differences between algorithms were similar for QRS duration and QT intervals in the normal and in the moxifloxacin subjects (mean ≤6 ms) but were significantly larger in patients with LQTS.Small but statistically significant group differences in mean interval and duration measurements and means of individual absolute differences exist among automated algorithms of widely used, current generation digital electrocardiographs. Measurement differences, including QRS duration and the QT interval, are greatest for the most abnormal ECGs.

Related Organizations
Keywords

Adult, Male, Reproducibility of Results, Signal Processing, Computer-Assisted, Equipment Design, Middle Aged, Electrocardiography, Heart Conduction System, Heart Rate, Humans, Female, Algorithms

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    54
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
54
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!