Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Energy Reportsarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Energy Reports
Article . 2023 . Peer-reviewed
License: CC BY
Data sources: Crossref
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Energy Reports
Article . 2023
Data sources: DOAJ
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Voltage and frequency regulation in smart grids via a unique Fuzzy PIDD2 controller optimized by Gradient-Based Optimization algorithm

Authors: Kareem M. AboRas; Muhammad Ragab; Mokhtar Shouran; Sultan Alghamdi; Hossam Kotb;

Voltage and frequency regulation in smart grids via a unique Fuzzy PIDD2 controller optimized by Gradient-Based Optimization algorithm

Abstract

This paper proposes a maiden intelligent controller design that consists of a Fuzzy Proportional–Integral–Derivative–Double Derivative (FPIDD2) controller whose parameters are fine-tuned using the Gradient-Based Optimization algorithm (GBO). The proposed FPIDD2 regulator is employed as a secondary regulator for stabilizing the combined voltage and frequency loops in a two-area interconnected power system. It has been shown that the GBO optimization algorithm outperforms other optimization strategies such as the Chimp Optimization Algorithm (ChOA), the Whale Optimization Algorithm (WOA), and the Gorilla Troops Optimization algorithm (GTO). The proposed FPIDD2 controller is tested in a conventional two-area power system. Then, the investigation is expanded to a two-area hybrid system, with each area comprising a mix of traditional (thermal, gas, and hydraulic power plants) and renewable generation units (wind and solar power). Additionally, the proposed controller takes into account system nonlinearities (such as generation rate limitations, governor deadband, and communication time delays), system uncertainties, and load/renewables fluctuations. In the two tested systems, the dynamic responses of each system demonstrate that FPIDD2 has a superior ability to attenuate the deviations in voltage and frequency in both areas of the system. In the studied conventional system, the proposed FPIDD2 controller is compared with a PID controller tuned by the Multi-Objective Non-Linear Threshold Accepting Algorithm (MONLTA), which has been presented in the literature, and a Fuzzy PID (FPID) controller tuned by GBO. In the investigated hybrid system, the suggested FPIDD2 regulator is compared to a GBO-tuned Integral Derivative-Tilted (ID-T) controller and FPID controller. As a fitness function (FF) for the GBO, the criteria of minimizing the integral time absolute error (ITAE) are applied. The results are presented in the form of MATLAB/SIMULINK time-domain simulations.

Related Organizations
Keywords

Fuzzy logic control, PIDD2 controller, Electrical engineering. Electronics. Nuclear engineering, Combined LFC-AVR, Two-area system, Renewable energy sources GBO algorithm, ITAE, TK1-9971

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    28
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
28
Top 10%
Top 10%
Top 10%
gold