Views provided by UsageCounts
General description Compressed archive containing the macro files and the scripts to run and analyze the results of the simulations of dose deposition in the BELLA A-Cave. The Geant4 scripts contain the parameters of the initial beam and of the computational mesh where the dose equivalent is deposited, the python scripts extract the data from the resulting OpenPMD files. The scripts include two possible configurations of shielding (Configuration 1 and Configuration 2) and the two initial beams investigated: a "realistic" distribution and an idealized 8 MeV monochromatic beam that represent the maximum point operationally achievable. Configurations Configuration 1: It includes the following permanent shielding Wall: the Cave A concrete walls, along with wall penetrations towards Cave B. All walls of Cave A are made of 36” thick concrete, except for the roof, the east wall and the entrance compartment walls which have a thickness of 24”. The penetrations for the beamline (from 1 to 3) and penetrations for the services (service penetrations in north, south, and east walls) are included in the simulations. Pb1 and Pb2: 8” thick Pb shielding filling the two wall penetrations towards Cave B which are closest to the Cave A interaction chamber. Pb3: A Pb plate (10” width, 10” height, 1” thickness) positioned at the exit of the interaction chamber, perpendicular to the beam axis. The plate has a square hole (4 cm side) centered at the position of the electron beam axis. Pb4: A Pb plate (20” width, 20” height, 1” thickness) placed at the west wall of Cave A, centered at the position of the electron beam axis. SS1 and SS2: stainless steel plates (2” thickness, 6” width, 2’ height) placed on both sides of the east wall, near the edges of penetration 3. The plates cover 3” of the window and 3” of the wall on both sides. The height of the plates is equal to the height of the opening. Configuration 2: In addition to the permanent shielding from Configuration 1, a tungsten (W) X-ray converter (0.5” width, 0.5” height, 2 mm thickness) is placed 3 cm downstream from the electron beam source. A 1”-wide and 4 cm long Pb shielding around the converter is considered. Description of the archive The archive is structure as follows inputs_and_macros ├── Configuration_1__8MeV │ ├── input.mac │ ├── plot_dose_1_100_mrem_per_hour.py │ └── print_dose_values.py ├── Configuration_1__exp_distribution │ ├── input.mac │ ├── khz_energy.dat │ ├── plot_dose_1_100_mrem_per_hour.py │ └── print_dose_values.py ├── Configuration_2__8MeV │ ├── input.mac │ ├── plot_dose_1_100_mrem_per_hour.py │ └── print_dose_values.py └── Configuration_2__exp_distribution ├── input.mac ├── khz_energy.dat ├── plot_dose_1_100_mrem_per_hour.py └── print_dose_values.py
BELLA, Geant4, A-Cave
BELLA, Geant4, A-Cave
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 6 |

Views provided by UsageCounts