Downloads provided by UsageCounts
ABSTRACT The aim of a quality assurance (QA) program is to assist a radio-diagnostic machine to obtaining adequate radiological quality information with a minimum of dose to the subject. An integrated part of a quality assurance program is Quality Control (QC) ascertaining quality by measurements and other procedures. QC in diagnostic radiography begins with production of predictable exposures. In this study the four tests (reproducibility, accuracy of kV, half value layer (HVL) and mAs linearity) were determined by Piranha X ray meter and were carried out for General X-Ray machine at Olaya Medical Complex. The QC tests have been carried out according to the intentional standard reports (AAPM No. 74) and National recommendations of King Abdullah City for Atomic & Renewable Energy. Various safety measures are taken by considering work personnel's safety. Thus, some QC tests were determined using the X-ray meter. For the accomplishment of this study, the tests of tube voltage accuracy and reproducibility, HVL and effective energy, air Kerma and air Kerma rate were performed, with their associated errors calculated. The obtained results were in the acceptable limits. The survey revealed that the QC program was conducted to this X-ray machine at regular intervals. Thus the calibration accuracy results Confirm that, the X-Ray E Machine Result is Pass. Keywords: Quality Assurance, Quality Control, X-Ray Machine, X-ray meter
Quality Assurance, Quality Control, X-Ray Machine, X-ray meter
Quality Assurance, Quality Control, X-Ray Machine, X-ray meter
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 6 | |
| downloads | 6 |

Views provided by UsageCounts
Downloads provided by UsageCounts