{"references": ["1. Apple DJ: \"Nicholas Harold Lloyd Ridley. 10 July 1906 - 25 May 2001: Elected FRS 1986\". Biogr Mems Fell R Soc, 2007;53:285-307", "2. Drews RC: Inflammatory response, endophthalmitis, corneal dystrophy, glaucoma, retinal detachment, dislocation, refractive error, lens removal, and enucleation. Ophthalmology, 1978;85(2):164-175.", "3. Lorusso V, Moramarco A, Pacella E, Balacco-Gabrieli C: Intraocular lens complications. Ann Ophthalmol, 1990;22(10):377-381.", "4. Goodman DF, Stark WJ, Gottsch JD: Complications of cataract extraction with intraocular lens implantation. Ophthalmic Surg, 1989;20(2):132-140", "5. Shepard DD: Indications for intraocular lens removal. Ophthalmic Surg, 1977;8(3):144-148.", "6. Kumar V, Nicholson L, Shankar J, Goel N: Possible causes for exposure of anterior chamber intraocular lens haptic tip. J Cataract Refract Surg, 2010;36(4):703.", "7. Gungel H, Altan C, Baylancicek DO: Endophthalmitis due to exposure of anterior chamber intraocular lens haptic tip. J Cataract Refract Surg, 2009;35(9):1633-1636.", "8. Teichmann KD:Propionibacterium acnes endophthal- mitis requiring intraocular lens removal after failure of medical therapy. J Cataract Refract Surg, 2000;26(7): 1085-1088", "9. Lewis JM, Eliott D: Extrusion of an anterior chamber intraocular lens complicated by Haemophilus endophthalmitis. Am J Ophthalmol, 1998;125(2):261-263.", "10. Price FW Jr, Whitson WE, Collins K, Johns S: Changing trends in explanted intraocular lenses: a single center study. J Cataract Refract Surg, 1992;18(5):470-474.", "11. Charles H, Peyman GA, Pang MP: Management of an extruded footplate of an anterior chamber lens with the Nd:YAG laser. J Cataract Refract Surg, 1987;13(3):313- 315."]}
A 45 year old male presented with partially exposed haptic loop of a tripod design anterior chamber intraocular lens (ACIOL) in the right eye. The best corrected vision was 20/60 right eye and 20/20 left eye. The patient refused surgical intervention of the right eye ACIOL in view of good vision. The patient was counselled against high risk of endophthalmitis and kept under close observation since last few years. We report a case of exposed loop of ACIOL since last 5 years with no complications
Anterior Chamber IOL, Explantation of IOL, Exposed Haptic
Anterior Chamber IOL, Explantation of IOL, Exposed Haptic
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 7 | |
| downloads | 6 |

Views provided by UsageCounts
Downloads provided by UsageCounts