Views provided by UsageCounts
Introduction This database includes the raw data linked with the paper “ Therapeutic Salivary Monitoring of Perampanel in Patients with Epilepsy Using a Volumetric Absorptive Microsampling Technique” published in “pharmaceutics”. The present work describes the development and validation of a volumetric absorptive microsampling (VAMS) method combined with liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the quantitative determination of the antiseizure medication perampanel in oral fluid and its clinical applicability in patients with epilepsy. VAMS tips were loaded with 30 μL of oral fluid, dried for 60 minutes and placed into clean tubes. Analytes were extracted with methanol and the samples were incubated at 50°C, sonicated and centrifuged. The supernatant was evaporated at room temperature under a gentle stream of nitrogen and reconstituted with 60 μL of methanol. Separation and quantification were achieved on a monolithic column connected to a mass spectrometer. Calibration curves were linear between 0.5 and 300 ng/mL. Intra- and inter-day accuracy was within 85.6-103.2% and intra-day and inter-day precision did not exceed 12.1%. Mean extraction recoveries ranged from 81.3% to 98.7%. Perampanel was stable in samples collected by VAMS and stored under different storage conditions. The developed VAMS-LC-MS/MS method was validated according to internationally accepted criteria and showed adequate bioanalytical performances holding great potential as alternative strategy to support domiciliary TDM in patients with epilepsy treated with perampanel according to the simplicity of samples collection.
saliva, volumetric absorptive miscrosampling, perampanel, therapeutic drug monitoring, LC-MS/MS
saliva, volumetric absorptive miscrosampling, perampanel, therapeutic drug monitoring, LC-MS/MS
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 10 |

Views provided by UsageCounts