Downloads provided by UsageCounts
{"references": ["1.\tMota, M. (2010) \"Voided slabs then and now\", 32(10), 41-45.", "2.\tAmer M. Ibrahim, Nazar K Ali, Wissam D Salman. (2013). \"Flexural capacities of reinforced two-way bubble deck slabs of plastic spherical voids\". Diyala Journal of Engineering Sciences, 6(2), 9-20.", "3.\tChung J. H., H. K., Lee, S.C., & Choi, C.S. (2014) \"Flexural strength and stiffness of biaxial hollow slab with donut type hollow sphere\". AIK Journal, Korea, 30(5), 3-11.", "4.\tCorey, J.M. (2013). \"Plastic voided slab system: Applications and design\". Manhattan, KS: Kansas State University.", "5.\tJoo-Hong Chung Hyun-Ki Choi et al, (2011) \"Punching Shear Design Method of Voided Slab\". Trans Tech Publication Switzerland, Vol, 452-453(2011), p.777-780.", "6.\tR.Sagadevan B.N. Rao. (2019). \"Effect of void former shapes on one way flexural behavior of biaxial hollow slabs\".", "7.\tA. Churakov, (2015). \"Biaxial hollow slab with innovative types of voids\", construction of unique buildings and structures. ISSN 2304-6295. 6(11). 2014.70-88", "8.\tConcrete reinforcing steel institutes (CSRI). (2014). \"Design guide for voided concrete slab\".ETN-B-4-17", "9.\tDiana Klein, \"Structural engineers, sustainability and LEED\". Eco- Integration sustainable design consulting.(2007).33P", "10.\tGuide for design of voided slab (2019).American Concrete Institute of Engineering in Civil and Environmental Engineering at the Massachusetts Institute of Technology, USA."]}
The plastic voided slab system in a building are seems effective and efficient in terms of economy, environmental sustainability as well as structural performances. Buildings with the plastic voided slab system are able to decrease the amount of concrete by 30 percent or more. It reduces the concrete from the mid height of slab where the concrete has no significant structural function. This paper presents, a building having two way reinforced concrete slab with the plastic voids construction in comparison with a building with the traditional solid flat slab construction under the same load carrying capacity. Stepped back building are taken for both the cases with common span of 7.5m in each direction and having column size 800mmx800mm for a building with the 310mm thick solid flat slab and column size 725mmx725mm for a building with the 230mm thick plastic voided slab consisting 180mm diameter spherical plastic balls. The solid flat slab design process follows the IS 456:2000 Code of practice for plain and reinforced concrete, direct design method. While the plastic voided slab design process is adapted from the bubble deck guide for compliance with the Indian standard. Results of comparison study are presented
Voided slab, Drift, Moment Distribution, Storey Stiffness, Modification Factor.
Voided slab, Drift, Moment Distribution, Storey Stiffness, Modification Factor.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 25 | |
| downloads | 368 |

Views provided by UsageCounts
Downloads provided by UsageCounts