The measure of left atrial pressure (LAP) is an ideal marker for the clinical efficacy of transcatheter mitral valve intervention. Currently, only the invasive measurement of LAP (i-LAP) is available and no echocardiographic methods are reliable in the setting of trans- catheter mitral valve intervention. This study sought to validate a new echocardiographic method for the estimation of LAP (e-LAP) by comparing it with i-LAP. During percutane- ous edge-to-edge procedure with MitraClip, the i-LAP was routinely monitored. Across the iatrogenic interatrial septum defect, the flow was sampled with continuous-wave Dopp- ler echocardiography for deriving the mean pressure gradient between the left atrium and the right atrium, and the central venous pressure was added to obtain the e-LAP. The cor- relation between the measures derived from these 2 methods was explored. A total of 34 consecutive patients were included. Intraclass correlation coefficient between e-LAP and i-LAP was high (intraclass correlation coefficient [95% confidence interval] 0.809 [0.625 to 0.902], R Pearson 0.6, p <0.001); a bias of 1.3 mm Hg for e-LAP versus i-LAP was found (p = 0.32). The median follow-up was 108 days (interquartile range 40 to 264). No death occurred and 6 patients were rehospitalized for heart failure. Postimplant e-LAP was correlated with rehospitalization at follow-up (hazard ratio 1.46, 95% confidence interval 1.022 to 2.1, p = 0.038). A cut-off value of 9.5 mm Hg for the e-LAP was identified as predictor of rehospitalization for heart failure. The evaluation of e-LAP has optimal reliability compared with i-LAP; a value more than 9.5 mm Hg was found to be related to higher risk of events at short follow-up. © 2022 Elsevier Inc. All rights reserved. (Am J Cardiol 2022;00:1−8)
Heart Failure, Cardiac Catheterization, Atrial Pressure, Treatment Outcome, Humans, Mitral Valve, Mitral Valve Insufficiency, Reproducibility of Results, Echocardiography, Transesophageal
Heart Failure, Cardiac Catheterization, Atrial Pressure, Treatment Outcome, Humans, Mitral Valve, Mitral Valve Insufficiency, Reproducibility of Results, Echocardiography, Transesophageal
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 3 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 3 |

Views provided by UsageCounts