Downloads provided by UsageCounts
The objective of this study was to perform a standard acquistion of dynamic PET perfusion measurements at the Turku PET centre using a dynamic test object (also known as a flow phantom). Images were acquired following the experimental protocol described in D2 of this project which is linked below. Once unzipped. there is a list of subfolders that are named using the convention SCANTYPE_PERCENTAGEFLOW_TOTALFLOW_FLOWINTUBE_RECONSTRUCTIONTYPE This naming convention describes and relates to some of the factors that we are varying in the experimental design protocol, specifically: SCANTYPE: type of scan; in the example “PT” stands for PET PERCENTAGEFLOW: percentage of flow going into the phantom main compartment; in the example, this value can be 20, 40, 60 or 80 %. TOTALFLOW: total flow rate set at the flow pump; in the example, it can be 150, 200 or 250 ml/min. FLOWINTUBE: the flow that goes into input tube as opposed to that going into the main compartment TOTALFLOW - COMPARTMENTFLOW RECONSTRUCTION TYPE: PET image reconstruction algorithm; in the example, it can be BSREM or OSEM Within each folder there is a dynamic sequence of images, stored as “.dcm” These images can be processed using the sofware tool provided in the GitLab repo with link below.
This project 19SIP04 TracPETperf has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme
dynamic flow phantom, quantification PET perfusion, phantom study
dynamic flow phantom, quantification PET perfusion, phantom study
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 20 | |
| downloads | 6 |

Views provided by UsageCounts
Downloads provided by UsageCounts