Views provided by UsageCounts
This record contains raw data related to article “Prognostic Value of Metabolic Imaging Data of 11 C-choline PET/CT in Patients Undergoing Hepatectomy for Hepatocellular Carcinoma" 11C-choline positron emission tomography/computed tomography (PET/CT) has been used for patients with some types of tumors, but few data are available for hepatocellular carcinoma (HCC). We queried our prospective database for patients with HCC staged with 11C-choline PET/CT to assess the clinical impact of this imaging modality. Seven parameters were recorded: maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), liver standardized uptake value (SUVliver), metabolic tumor volume (MTV), photopenic area, metabolic tumor burden (MTB = MTVxSUVmean), and SUVratio (SUVmax/SUVliver). Analysis was performed to identify parameters that could be predictors of overall survival (OS). Sixty patients were analyzed: fourteen (23%) were in stage 0-A, 37 (62%) in stage B, and 9 (15%) in stage C of the Barcelona classification. The Cox regression for OS showed that Barcelona stages (HR = 2.94; 95%CI = 1.41-4.51; p = 0.003) and MTV (HR = 2.11; 95%CI = 1.51-3.45; p = 0.026) were the only factors independently associated with OS. Receiver operating characteristics curve analysis revealed MTV ability in discriminating survival (area under the curve (AUC) = 0.77; 95%CI = 0.57-097; p < 0.001: patients with MTV ≥ 380 had worse OS (p = 0.015)). The use of 11C-choline PET/CT allows for better prognostic refinement in patients undergoing hepatectomy for HCC. Incorporation of such modality into HCC staging system should be considered.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 8 |

Views provided by UsageCounts