Downloads provided by UsageCounts
Introduction and Aims: Difficult laryngoscopy [poor visualisation of larynx] is a surrogate indicator of difficult intubation and inability to manage difficult visualisation of larynx (DVL) can be life threatening. This study is performed to assess the ability of new index –Acromio -Axillo-Suprasternal Notch Index to predict difficult laryngoscopy in patient undergoing general anaesthesia in addition to other common predictors. Material and Methods: 100 patients with ASA class I and II candidate for general anaesthesia with endotracheal intubation were enrolled to this study. The four usual tests Modified MallampatiTest[MMT], Ratio Of Height to Thyromental Distance[RHTMD], Neck Circumference/ Thyromental distance, Sternomental distance difference were assessed before induction of anaesthesia. The new test AASI is calculated as follow: 1) Using a ruler a line is drawn vertically from the top of the acromion process to the superior border of the axilla at the pectoralismajor muscle named as line A. 2) A second line is drawn perpendicular to line A from the suprasternal notch (line B) and 3)That portion of line A that lies above where line B bisects line A is line C. AASI is calculated from the length of line C divided by line A[AASI = C/A]. By a skilled anaesthesiologist with more than 5 years of experience & who was unaware of the study, A laryngoscopy was done and based on Cormack-Lehane classification, grading of laryngoscopy was recorded. Sensitivity, specificity, positive predictive value and negative predictive value with 95% Confidence Interval for each airway predictor in isolation was studied. Results: DVL observed in 12% patients. We observed that sensitivity,specificity,PPV,NPV,AUC of Roc[95% confidence interval] of AASI was 80%[44.4-97.5%], 95.56%[89-98.8%],66.67%[42.22-84.6%],97.7%[92.6-99.33%},0.985[0.898-0.988]respectively & these results are better than other conventional methods of difficult airway predictors. Conclusion: AASI more than or equal to 0.5 is a good predictor of difficult visualisation of larynx (DVL) at direct laryngoscopy.
AASI Difficult Visualisation of Larynx
AASI Difficult Visualisation of Larynx
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 4 | |
| downloads | 3 |

Views provided by UsageCounts
Downloads provided by UsageCounts