Abstract. Summary: the objective of this preliminary evaluation is to determine the set-up reproducibility of a commercially available pelvis and abdomen immobilization system and compatible pelvis thermoplastic masks. Material and method: to carry out this evaluation we used the pelvis and abdomen immobilization system, PEL-FIX / eaSyGroin (AnatGe), compatible pelvis thermoplastic masks, eXaCast (AnatGe) and an Alderson Radiation Therapy (ART) human-like phantom. The phantom was placed on the immobilization system and immobilized with a thermoplastic mask previously softened during 1 to 2 minutes on a water bath. Once the mask was placed on the phantom and hardened, a CT scan was acquired and the mask is removed. The images were sent to Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI). Two days later, the immobilization process of the phantom was repeated, the verification CT images were acquired and sent to the TPS. This process was repeated during 10 days and we acquired 5 groups verification CT images, that were analyzed in the fusion application of the TPS (Fig.1). Results: The data set obtained from 5 CTs groups of phantom's repositioning were analyzed to get the following average of set-up errors: 0,21 mm (longitudinal), 0,18 mm (lateral) and 0,12 mm (Vertical). Conclusion: This immobilization system is a workable solution. This system offers great adaptability to the morphology of the patient, which leads to improve precision and reproducibility of abdominal and pelvis area in radiotherapy treatments.
Immobilization, SBRT, thermoplastic masks, radiotherapy, cancer treatment
Immobilization, SBRT, thermoplastic masks, radiotherapy, cancer treatment
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 2 | |
| downloads | 1 |

Views provided by UsageCounts
Downloads provided by UsageCounts