Background: Quantitative SPECT of the lungs after intra-arterial hepatic radioembolization using Holmium-166 (166Ho)microspheres is essential to assess therapy safety. A SPECT estimated lung absorbed dose resulting from radioembolization of more than 30 Gy is a contra-indication for therapy. Earlier we showed the superiority of Monte Carlo-based iterative reconstructions over conventional reconstructions due to its quantitative nature, required for dosimetry, at the cost of substantial computation times. In clinical routine, however, the limited available time between scout imaging and therapy constrains its application. To reduce computation times, we investigated the minimum number of iterations required to guarantee a clinical acceptable accuracy in lung dose estimation using patient and phantom data. Methods: 166Ho scout SPECT data (range: 222-283 MBq) were used from 9 patients. SPECT images were Monte Carlo-based OSEM reconstructed (iterations: 30, subsets: 8). Additionally, the 4D XCAT anthropomorphic phantom was used to mimic SPECT studies with an injected scout activity of 250 MBq and with varying lung doses ranging from 0 to 15.6 mGy/MBq. These studies were reconstructed in the same way as the patient data. Results: In all patients the lung absorbed dose upon OSEM convergence ranged from 0 to 0.025 mGy/MBq, and ranged from 0.002 to 0.078 mGy/MBq after five iterations, still well below the allowed 30 Gy in case treatment was proceeded. In the phantom data, the estimated lung dose ranged from 0.004 to 15 mGy/MBq upon convergence and from 0.03 to 13.9 mGy/MBq after five iterations, simulating situations well below and above an estimated treatment lung dose of 30 Gy. Importantly, the lung absorbed dose upon OSEM convergence was underestimated by 15% as compared to the actual simulated lung dose, and the dose after five OSEM iterations was underestimated by 9% as compared to the dose upon convergence. Both underestimations were irrespective of the magnitude of the lung dose and thus can be easily corrected for. Conclusions: The number of OSEM iterations necessary for a quantitative estimate of the lung dose can be reduced from 30 to 5. The resulting six fold reduction in calculation time enables data processing of the scout images before therapy administration.
radioembolization, iterative reconstruction, Holmium-166 microspheres, interventional oncology, Quantitative SPECT
radioembolization, iterative reconstruction, Holmium-166 microspheres, interventional oncology, Quantitative SPECT
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 12 | |
| downloads | 121 |

Views provided by UsageCounts
Downloads provided by UsageCounts