Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: ZENODO
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: Datacite
versions View all 2 versions
addClaim

Fault test cases for series compensated transmission line with capacitor at line terminal

Authors: Tanbhir, ;

Fault test cases for series compensated transmission line with capacitor at line terminal

Abstract

This data set contains time series data of different simulated fault cases in high voltage series compensated transmission lines. The simulation is done in PSCAD using the Python automation library. The capacitor is located at one of the line terminals with CT and VT. The modelled line is 500 kV and 200 km long. The simulation is run for 1 second with 10 kHz sampling rate. Each file contains 7 data in the following order, Time Voltage phase A Voltage phase B Voltage phase C Current phase A Current phase B Current phase C The variables used to study different test cases are shown below, Fault inception angle (phase A): 0 and 90 degree Source impedance ratio: 0.20 and 0.35 Capacitor level: 94 µF(50%), 78 µF(60%), 67 µF(70%) Fault resistance: 0.10, 10, 20, 30 ohm Fault location: 10 km reverse, 10 km, 50 km, 100 km, 125 km, 150 km, 155 km, 160 km. 165 km, 170 km, 180 km, 190 km Fault type: No-fault, AG, BG, CG, ABG, CAG, BCG, ABCG, AB, CA, BC, ABC All these factors lead to 6912 test cases in total. The test cases are organized in four (4) zipped folders each containing 1728 test cases. The PSCAD model file and an example python script that can be used to automate the simulations are also included herewith for anyone interested to replicate the results. The name of the folder contains the information regarding fault inception angle and source impedance ratio for all test cases inside that folder, for example, the folder name Outputs_0_0.20 can be decoded as, 0: Fault inception angle (phase A) 0.20: Source impedance ration The files names inside the folders include information about the other variables used in generating the test case. For example, the name test_f_10_0_67_0.01 can be interpreted as, test_f: f for forward fault, r for reverse fault 10: fault location, 10 km 0: Fault type 67: Compensation level 0.01: Fault resistance Fault types are interpreted as in PSCAD. 0 = No-Fault, 1 = Phase A to Ground 2 = Phase B to Ground 3 = Phase C to Ground 4 = Phase AB to Ground 5 = Phase AC to Ground 6 = Phase BC to Ground 7 = Phase ABC to Ground 8 = Phase AB 9 = Phase AC 10 = Phase BC 11 = Phase ABC The different line parameters used in the PSCAD model is as below, Conductor Type: Chukar Geometric mean radius: 20.345 mm DC resistance: 0.0318Ω/km Strands: 84 Strand radius: 1.8491 mm Relative permeability: 1.0 Sag: 12 m Height: 22 m Sub-conductor: 2 Sub-conductor spacing: 0.4572 m Ground wire number: 2 Radius: 5.5245 mm DC resistance: 2.8645Ω/km Relative permeability: 1.0 Sag: 10 m Height: 10 m Impedance Positive sequence0.018 +j0.339 Ω/km Zero sequence0.266 +j1.017 Ω/km These simulations were run for assessing time-domain protections. Therefore, the parallel CB protection across the series capacitor is disabled, as one can safely assume even with the highest current levels, the CB will take at least 20 ms to operate. This is higher than the time limits for time-domain protection.

This work was funded through SweGRIDS, by the Swedish energy agency, Hitachi ABBPower Grids and the Swedish transmission network operator Svenska kraftnät.

Keywords

series compensated line, PSCAD, transmission line, fault data, time series, series compensation

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 33
    download downloads 26
  • 33
    views
    26
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
33
26