Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: ZENODO
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2021
License: CC BY
Data sources: Datacite
versions View all 2 versions
addClaim

Experimental cooling data in KUBIK lab-building during the 2020 season. HOLISDER project pre-pilot testing activities.

Authors: de Agustin Camacho, Pablo; Eguiarte, Olaia;

Experimental cooling data in KUBIK lab-building during the 2020 season. HOLISDER project pre-pilot testing activities.

Abstract

The data in this dataset is derived from the one of the pre-validation tests of the HOLISDER European project http://holisder.eu/ . The testing premises consist of an enclosed area in the ground floor of KUBIK by TECNALIA Research & Innovation (a three floors experimental buildings, including an underground basement where central HVAC equipment are located). The ground floor is cooled through two fan-coil, as terminal units, while the cooling generation was performed by two chillers located in the basement. The SCADA system of the building records operation temperatures, mass flows, delivered power, fan-coils operation volume, setpoint temperatures and operation modes. The test was carried out from 01/07/20 to 31/10/2020 under strict cooling comfort boundaries in order to characterize the premise’s systems. One file is provided as a xlsx file with the following features with 10-minute frequency: (Disclaimer: Provided dataset is raw-data and null or error values were not deleted from it) Weather station METEO_RoofSR_Global.PV: Global horizontal radiation METEO_GardenWS_AT.PV: Outdoor dry bulb temperature FANCOIL 1 F0N2_FCM1.Enable: Fancoil1 enabled F0N2_FCM1.PV: Fancoil1 thermostat reading F0N2_FCM1.SP: Fancoil1 thermostat setpoint F0N2_FCM1.ST_COOL_Mode: Fancoil on cooling mode F0N2_FCM1.ST_HOT_Mode: Fancoil on heating mode F0N2_FCM1.ST_VENT_Mode : Fancoil on fan mode F0N2_FCM1_C5.PV: Inlet water flow F0N2_FCM1_ST1.PV: Inlet water temperature F0N2_FCM1_ST2.PV: Outlet water temperature F0N2_FCM1_W5.kWh: Cumulative thermal supply F0N2_FCM1_W5.kWh_AC: Cumulative heat F0N2_FCM1_W5.kWh_AF: Cumulative cold F0N2_FCM1_W5.W: Thermal power FANCOIL 2 F0N2_FCM2.Enable: Fancoil2 enabled F0N2_FCM2.PV: Fancoil2 thermostat reading F0N2_FCM2.SP: Fancoil2 thermostat setpoint F0N2_FCM2.ST_COOL_Mode: Fancoil on cooling mode F0N2_FCM2.ST_HOT_Mode: Fancoil on heating mode F0N2_FCM2.ST_VENT_Mode : Fancoil on fan mode F0N2_FCM2_C6.PV: Inlet water flow F0N2_FCM2_ST1.PV: Inlet water temperature F0N2_FCM2_ST2.PV: Outlet water temperature F0N2_FCM2_W6.kWh: Cumulative thermal supply F0N2_FCM2_W6.kWh_AC: Cumulative heat F0N2_FCM2_W6.kWh_AF: Cumulative cold F0N2_FCM2_W6.W: Thermal power CHILLER 1 HVAC_BP301.OUT: Impulsion pump to distribution order HVAC_CP301.PV: Outlet cold water flow HVAC_ENF1_CVM.Hz: Frequency HVAC_ENF1_CVM.I_III: Average Intensity HVAC_ENF1_CVM.IR: Intensity phase R HVAC_ENF1_CVM.IS: Intensity phase S HVAC_ENF1_CVM.IT: Intensity phase T HVAC_ENF1_CVM.kVArh_in: Reactive Energy (R+) HVAC_ENF1_CVM.kVArh_out: Reactive Energy (R-) HVAC_ENF1_CVM.kWh_in: Active Energy A+) HVAC_ENF1_CVM.kWh_out: Active Energy (A-) HVAC_ENF1_CVM.PF_III: Power factor (average) HVAC_ENF1_CVM.PF_R: Power factor phase R HVAC_ENF1_CVM.PF_S: Power factor phase S HVAC_ENF1_CVM.PF_T: Power factor phase T HVAC_ENF1_CVM.V_III: Combined Voltage HVAC_ENF1_CVM.VA: Apparent Power HVAC_ENF1_CVM.Var: Reactive Power HVAC_ENF1_CVM.VRS: Phases R-S combined voltage HVAC_ENF1_CVM.VST: Phases S-T combined voltage HVAC_ENF1_CVM.VTR: Phases T-R combined voltage HVAC_ENF1_CVM.W: Active Power HVAC_ENF1_m.OUT: Turning on order HVAC_Enfriadora1.SP: Control setpoint HVAC_SP301.PV: Cold water outlet HVAC_SP302.PV: Cold water inlet HVAC_WP301.kWh: Cumulative thermal energy produced (cold) HVAC_WP301.W: Thermal power (cold) CHILLER 2 HVAC_BP401.OUT: Impulsion pump to distribution order HVAC_CP401.PV: Outlet cold water flow HVAC_ENF2_CVM.Hz: Frequency HVAC_ENF2_CVM.I_III: Average Intensity HVAC_ENF2_CVM.IR: Intensity phase R HVAC_ENF2_CVM.IS: Intensity phase S HVAC_ENF2_CVM.IT: Intensity phase T HVAC_ENF2_CVM.kVArh_in: Reactive Energy (R+) HVAC_ENF2_CVM.kVArh_out: Reactive Energy (R-) HVAC_ENF2_CVM.kWh_in: Active Energy A+) HVAC_ENF2_CVM.kWh_out: Active Energy (A-) HVAC_ENF2_CVM.PF_III: Power factor (average) HVAC_ENF2_CVM.PF_R: Power factor phase R HVAC_ENF2_CVM.PF_S: Power factor phase S HVAC_ENF2_CVM.PF_T: Power factor phase T HVAC_ENF2_CVM.V_III: Combined Voltage HVAC_ENF2_CVM.VA: Apparent Power HVAC_ENF2_CVM.Var: Reactive Power HVAC_ENF2_CVM.VRS: Phases R-S combined voltage HVAC_ENF2_CVM.VST: Phases S-T combined voltage HVAC_ENF2_CVM.VTR: Phases T-R combined voltage HVAC_ENF2_CVM.W: Active Power HVAC_ENF2_m.OUT: Turning on order HVAC_Enfriadora2.SP: Control setpoint HVAC_SP401.PV: Cold water outlet HVAC_SP402.PV: Cold water inlet HVAC_WP401.kWh: Cumulative thermal energy produced (cold) HVAC_WP401.W: Thermal power (cold) Chillers room temperature HVAC_STA.PV: Air temperature in the basement where chillers are located (point A) HVAC_STB.PV: Air temperature in the basement where chillers are located (point B) HVAC_STC.PV: Air temperature in the basement where chillers are located (point C) HVAC_STD.PV: Air temperature in the basement where chillers are located (point D)

Keywords

fan-coil, SCADA, cooling demand, Space cooling data

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 3
  • 3
    views
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
0
Average
Average
Average
3