Test Sample Specifications Configuration: 5P5S (5 cells in parallel (bank), 5 banks in series) Module Nominal Capacity = 16.5 Ah Graphite / NCA Cells Pouch Cells Cycling Protocol Charge: CCCV at C/2 up to 21.0 V and a C/100 cutoff current Discharge: CC at C/2 down to 13.5 V Cycling Life Number of Cycles = 2000 Capacity Fade = 20.00 %
Lithium-ion Batteries, State of Health, Pouch Cell, Modules, Cycle Life, Aging Test
Lithium-ion Batteries, State of Health, Pouch Cell, Modules, Cycle Life, Aging Test