Introduction: cardiac surgery is continuosly evolving towards a less invasive procedures and different perfusion techniques are also being studied to enhance the results. The aim of this study is to propose a standardized minimized extracorporeal circuit (MiECC) design to guarantee a fix low contact surface and haemodilution when the haematic antegrade repriming (HAR) is being applied. Materials and Methods: after a review of the current evidence a minimized circuit of 3/8 inch diameter was proposed and approved by our cardiac surgery team. Results: The initial dynamic priming of the circuit is lower than 1000ml. After HAR maneuvres, the haemodilution is reduced to 300ml of crystalloid priming. Discussion: The standardization of the circuit reduces errors, offers continuity between centres and savings. The basis of HAR are the detailed and reproducibile measures that could exceed the benefits of the isolated effect of reducing the circuit, applying vacuum to increase the drainage or retrogradely repriming it with blood. As a differencing factor, the standardization and detailing of the procedure offers reproducible results that should be assessed. Conclusion: Detailing the MiECC circuit used during HAR is a differencing feature that increases the replicability of the procedure reducing errors and the impact of the cardiopulmonary bypass.
minimized extracorporeal circuit, cardiopulm onary bypass, perfusion, haematic antegrade repriming, HAR, minimum impact cardiac surgery
minimized extracorporeal circuit, cardiopulm onary bypass, perfusion, haematic antegrade repriming, HAR, minimum impact cardiac surgery
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 7 | |
| downloads | 4 |

Views provided by UsageCounts
Downloads provided by UsageCounts