Objective: Despite the fact that the ear is the site to monitor arterial oxygen saturation by pulse oximetry (SpO2) closest to carotid chemoreceptors, sleep studies almost invariably use finger probes. This study aimed to assess the timing and morphological differences between SpO2 signals at the ear and finger during Cheyne-Stokes respiration (CSR) in heart failure (HF) patients. Methods: We studied 21 HF patients with CSR during a 40-min in-laboratory resting recording. SpO2 was recorded by: (1) two identical bedside pulse-oximeters with an ear (SpO2_Ear) and a finger probe (SpO2_Finger), and (2) a standard polysomnograph with a finger probe (SpO2_PSG). We estimated the delays between signals and, for each signal, computed the mean and minimum SpO2, the magnitude of cyclic desaturations and the overall time spent with SpO2<90% (T90%). Results: The SpO2_Finger signal was significantly delayed [bias: 12.7 s (95% limits of agreement: 2.2, 23.0 s)] and slightly but not significantly downward-shifted with respect to SpO2_Ear. SpO2_PSG was almost synchronous with SpO2_Finger; however, a further significant downward shift was observed relative to the latter. In particular, minimum SpO2_PSG was significantly lower [-2.1% (- 4.8, 0.6%)], and desaturations and T90% were significantly higher than SpO2_Finger [1.2% (-1.3, 3.7%), and 13.9% (-12.3, 40.0%), respectively]. Conclusion: During CSR in HF patients, the marked delay between SpO2_Ear and SpO2_Finger makes the interpretation of the timing relationship between peripheral chemoreceptor stimulation and ventilatory events rather difficult. The observed discrepancies between SpO2_PSG and SpO2_Finger, which may be due to differences in the processing of raw SpO2 signals, call for a standardization of processing algorithms.
Heart Failure, Male, Finger probe, Polysomnography, Ear probe, Ear, Heart failure, Middle Aged, Cheyne-Stokes respiration, Fingers, Pulse oximetry, Oxygen Consumption, Tidal Volume, Humans, Female, Oximetry, Prospective Studies, Cheyne-Stokes Respiration, Aged
Heart Failure, Male, Finger probe, Polysomnography, Ear probe, Ear, Heart failure, Middle Aged, Cheyne-Stokes respiration, Fingers, Pulse oximetry, Oxygen Consumption, Tidal Volume, Humans, Female, Oximetry, Prospective Studies, Cheyne-Stokes Respiration, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 6 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 3 |

Views provided by UsageCounts