Powered by OpenAIRE graph
Found an issue? Give us feedback
ZENODOarrow_drop_down
ZENODO
Article . 2026
License: CC BY
Data sources: Datacite
ZENODO
Article . 2026
License: CC BY
Data sources: Datacite
versions View all 2 versions
addClaim

A prospective randomized controlled study to compare two supraglottic airway devices LMA-ProtectorTM and LMA-ProSealTM in anaesthetized patients

Authors: Dr. Garima Agrawal , Dr. Vishal Kant , Dr. Raksha Kundal , Dr. Shubhangi Sudan , Dr. Rishu Parihar;

A prospective randomized controlled study to compare two supraglottic airway devices LMA-ProtectorTM and LMA-ProSealTM in anaesthetized patients

Abstract

Background: Laryngeal mask airway (LMA)-ProSealTM has been in use for a long time and has stood the test of time. LMA ProtectorTM is a composite of various supraglottic devices, and like LMA ProSeal, it promises high oropharyngeal leak pressures and gastric access. It has a preformed curved shaft like LMA FastrackTM, LMA SupremeTM and LMA AuragainTM, and it is a single-use device like LMA SupremeTM and LMA uniqueTM. Besides, LMA ProtectorTM has two unique features: a dual gastric port and an in-built intracuff pressure monitor. We found sparse literature on LMA Protector, and only a few research papers compare LMA Protector with LMA ProSeal. We aimed to compare the device's clinical performance regarding oropharyngeal leak pressure (OLP) and LMA insertion time, the ease of orogastric tube insertion, and the severity of sore throat. Results: OLP was significantly higher in the LMA Protector group compared to the LMA ProSeal group (34.8±3.5cmH20 vs 31.7±4.5 cmH20, p = 0.001). LMA insertion time was considerably longer with LMA Protector (25.7±5.2 sec vs 23.4±5.3 sec; p = 0.047). The ease of LMA insertion was comparable. Gastric tube insertion was grade 1 in the majority of patients. Incidence and severity of postoperative sore throat at 2 and 24 hours were similar in both groups. Conclusion: Compared to LMA ProSealTM, LMA ProtectorTM achieved a better oropharyngeal seal by attaining higher oropharyngeal leak pressures. LMA Protector's observed 7.5% initial insertion failure rate though statistically insignificant as a key clinical consideration when first-attempt success is critical. Insertion characters of both the devices were similar.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!