image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Article
Data sources: ZENODO
addClaim

Intelligent Fault Detection in Smart Distribution Grids Using Bidirectional LSTM-CNN Ensemble

Authors: Archana Bhattacharya, Dinesh Kumar Palaniswamy;

Intelligent Fault Detection in Smart Distribution Grids Using Bidirectional LSTM-CNN Ensemble

Abstract

incorporating advanced metering infrastructure, distributed generation, and real-time supervisory control. Within this context, rapid and accurate fault detection and classification has acquired renewed urgency: the Bureau of Indian Standards estimates that uncleared distribution faults contribute approximately 31% of total technical losses on 11 kV feeders in Tier-2 Indian cities, and the average fault clearance time of 4.7 minutes in manually operated systems significantly exceeds the 0.5-minute target of SCADA-integrated digital relay systems. Traditional protective relay algorithms based on overcurrent and distance principles struggle with high-impedance faults, evolving distributed generation fault contributions, and complex multi-terminal feeder topologies that characterise modern Indian distribution networks.This study presents a deep learning-based fault detection and classification system combining Bidirectional Long Short-Term Memory (BiLSTM) networks for temporal feature extraction with a parallel one-dimensional Convolutional Neural Network (CNN-1D) for frequency-domain feature extraction, fused through a learned attention mechanism. The model is trained on 18,500 labelled fault events — covering six fault types (no-fault, LG, LL, LLG, 3LG, and open conductor) under 48 loading and generation scenarios — generated from a validated PSCAD/EMTDC model of the 47-bus Coimbatore zone 11 kV distribution network built from actual TNEB feeder data. SHAP (SHapley Additive exPlanations) values provide feature-level explainability for utility engineer acceptance.The proposed BiLSTM-CNN ensemble achieves 99.3% classification accuracy with 99.7% sensitivity, 99.1% specificity, and mean fault location error of 1.3% across all six fault classes, outperforming standalone LSTM (97.1%), CNN-1D (96.8%), and the SVM baseline (93.4%). Detection latency of 18.3 ms satisfies IEC 61850 GOOSE message timing requirements for digital substation protection, confirming practical deployment viability in Tamil Nadu's expanding smart grid infrastructure.

Powered by OpenAIRE graph
Found an issue? Give us feedback