Downloads provided by UsageCounts
doi: 10.5281/zenodo.16838
Authors:Brian Brown Date:27th November 1981Brief Description:Data were recorded from Rod Smallwoood's arm on the 27th November 1981; the dot matrix image which shows the ulna and radius bones. We made a 'radiotherapy type' mould of the arm and then put drawing pins through the plastic (pin head inwards) as electrodes. There two sets of data. One is recorded from the arm and the other is with saline filling the mould. The data were published in: D.C. Barber, B.H. Brown, and I.L. Freeston, "Imaging spatial distributions of resistivity using applied potential tomography", Electronics Letters, 19(22):933-935, 1983 http://digital-library.theiet.org/content/journals/10.1049/el_19830637 License:Creative Commons Artistic License (with Attribution)Attribution Requirement:Use or presentation of these data reference this publication: D.C. Barber, B.H. Brown, and I.L. Freeston, "Imaging spatial distributions of resistivity using applied potential tomography", Electronics Letters, 19(22):933-935, 1983 Format:Data are handwritten and scanned into the linked pdf file. The adjacent drive/receive data sets for both the Uniform(Saline) and Arm data and these are included in the attached Excel file. The are 6 columns of data in the xls file. The first three are for the uniform case and give the two reciprocal data sets and the mean of the two. Columns 4-6 are for the arm. I did a quick reconstruction using columns 3 and 6 as ref and data respectively and it looked OK. Methods:The pdf file that is attached shows the line printer output of the data we recorded from Rod Smallwoood's arm on the 27th November 1981 and the dot matrix image which shows the ulna and radius bones. We made a 'radiotherapy type' mould of the arm and then put drawing pins through the plastic (pin head inwards) as electrodes. There two sets of data. One is recorded from the arm and the other is with saline filling the mould. The pdf file also shows my plot of the XY position of the electrodes. Now the data set on the line printer is a complete data set i.e. Drive 1/2 then 1/3 then 1/4 etc for every combination. I could only find the print out for one of the data sets. However, I found my notebook with the adjacent drive/receive data set and this is page 7 of the pdf file. I have extracted the adjacent drive/receive data sets for both the Uniform(Saline) and Arm data and these are included in the attached Excel file. The are 6 columns of data in the xls file. The first three are for the uniform case and give the two reciprocal data sets and the mean of the two. Columns 4-6 are for the arm. I did a quick reconstruction using columns 3 and 6 as ref and data respectively and it looked OK. The first column of data is 104 point as follows. Drive 1/2 receive 3/4 Drive 1/2 receive 4/5 etc Drive 1/2 receive 16/1 Drive 2/3 receive 4/5 Drive 2/3 receive 5/6 etc Drive 2/3 receive 16/1 Drive 4/5 receive 6/7 Drive 4/5 receive 7/8 etc Drive 4/5 receive 16/1 etc etc Drive 14/15 receive 16/1 The second column is the other reciprocal set. I think these data are the ones used to produce the image in the Electronics Letters paper of 1983 - page 1 of my pdf file.
Also in the Contributed Data section of the EIDORS project on Sourceforge http://eidors3d.sourceforge.net/data_contrib/bb-human-arm/bb-human-arm.shtml
Electrical Impedance Tomograph, Human arm
Electrical Impedance Tomograph, Human arm
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 9 | |
| downloads | 10 |

Views provided by UsageCounts
Downloads provided by UsageCounts