Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Dataset . 2025
License: CC BY
Data sources: ZENODO
ZENODO
Dataset . 2025
License: CC BY
Data sources: Datacite
ZENODO
Dataset . 2025
License: CC BY
Data sources: Datacite
versions View all 2 versions
addClaim

Evaluation of fetal exposure to environmental noise using a computer-generated model: Data

Authors: Gélat, Pierre; van 't Wout, Elwin; Haqshenas, Reza; Melbourne, Andrew; David, Anna Louise; Mufti, Nada; Thibaut de Maisières, Aude; +2 Authors

Evaluation of fetal exposure to environmental noise using a computer-generated model: Data

Abstract

Figure 1A-D Connectivity list files contain the topology of triangular surface mesh elements for Subjects 1, 2, 3 and 4. Points files contain x, y and z values of the mesh vertices in mm Subjects 1, 2, 3 and 4. Figures 2A-L Column 1: Frequency (Hz) Column 2: Low-attenuation SPL (dB re 1 Pa) Column 3: High-attenuation SPL (dB re 1 Pa) Figures 3A-C and 3G-I data files contain the SPL re 1Pa at the vertices of the surface meshes of the 3 key anatomical groups (abdomen, spine, uterus). The field SPL is the same data as in the 2D plots. Column 1: x (m) Column 2: y (m) Column 3: z (m) Column 4: SPL (dB re 1 Pa) Figures 3D-F and 3J-L contain 4 block matrices of 251 columns each in meshgrid format: Block matrix 1: x (m) Block matrix 2: y (m) Block matrix 3: z (m) Block matrix 4: SPL (dB re 1 Pa) Figures 4A-C and 4G-I data files contain the SPL re 1Pa at the vertices of the surface meshes of the 3 key anatomical groups (abdomen, spine, uterus). The field SPL is the same data as in the 2D plots. Column 1: x (m) Column 2: y (m) Column 3: z (m) Column 4: SPL (dB re 1 Pa) Figures 4D-F and 4J-L contain 4 block matrices of 251 columns each in meshgrid format: Block matrix 1: x (m) Block matrix 2: y (m) Block matrix 3: z (m) Block matrix 4: SPL (dB re 1 Pa) Figures 5A-C and 5G-I data files contain the SPL re 1Pa at the vertices of the surface meshes of the 3 key anatomical groups (abdomen, spine, uterus). The field SPL is the same data as in the 2D plots. Column 1: x (m) Column 2: y (m) Column 3: z (m) Column 4: SPL (dB re 1 Pa) Figures 5D-F and 5J-L contain 4 block matrices of 251 columns each in meshgrid format: Block matrix 1: x (m) Block matrix 2: y (m) Block matrix 3: z (m) Block matrix 4: SPL (dB re 1 Pa) Figures 6A-C and 6G-I data files contain the SPL re 1Pa at the vertices of the surface meshes of the 3 key anatomical groups (abdomen, spine, uterus). The field SPL is the same data as in the 2D plots. Column 1: x (m) Column 2: y (m) Column 3: z (m) Column 4: SPL (dB re 1 Pa) Figures 6D-F and 6J-L contain 4 block matrices of 251 columns each in meshgrid format: Block matrix 1: x (m) Block matrix 2: y (m) Block matrix 3: z (m) Block matrix 4: SPL (dB re 1 Pa) Figure 7A and 7B data Column 1: Frequency (Hz) Column 2: Low attenuation OptimUS solution (dB re 1 Pa) Column 3: High attenuation OptimUS solution (dB re 1 Pa) Column 4: Low attenuation analytical solution (dB re 1 Pa) Column 5: High attenuation analytical solution (dB re 1 Pa) Figure 7C-H Contains 4 block matrices of 250 columns each in meshgrid format Block matrix 1: x data (m) Block matrix 2: y data (m) Block matrix 3: z data (m) Block matrix 4: acoustic pressure magnitude data (Pa) Figures 8A and 8B Column 1: sample number Column 2: impulse response (re 1 Pa)

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average