
Figure 1A-D Connectivity list files contain the topology of triangular surface mesh elements for Subjects 1, 2, 3 and 4. Points files contain x, y and z values of the mesh vertices in mm Subjects 1, 2, 3 and 4. Figures 2A-L Column 1: Frequency (Hz) Column 2: Low-attenuation SPL (dB re 1 Pa) Column 3: High-attenuation SPL (dB re 1 Pa) Figures 3A-C and 3G-I data files contain the SPL re 1Pa at the vertices of the surface meshes of the 3 key anatomical groups (abdomen, spine, uterus). The field SPL is the same data as in the 2D plots. Column 1: x (m) Column 2: y (m) Column 3: z (m) Column 4: SPL (dB re 1 Pa) Figures 3D-F and 3J-L contain 4 block matrices of 251 columns each in meshgrid format: Block matrix 1: x (m) Block matrix 2: y (m) Block matrix 3: z (m) Block matrix 4: SPL (dB re 1 Pa) Figures 4A-C and 4G-I data files contain the SPL re 1Pa at the vertices of the surface meshes of the 3 key anatomical groups (abdomen, spine, uterus). The field SPL is the same data as in the 2D plots. Column 1: x (m) Column 2: y (m) Column 3: z (m) Column 4: SPL (dB re 1 Pa) Figures 4D-F and 4J-L contain 4 block matrices of 251 columns each in meshgrid format: Block matrix 1: x (m) Block matrix 2: y (m) Block matrix 3: z (m) Block matrix 4: SPL (dB re 1 Pa) Figures 5A-C and 5G-I data files contain the SPL re 1Pa at the vertices of the surface meshes of the 3 key anatomical groups (abdomen, spine, uterus). The field SPL is the same data as in the 2D plots. Column 1: x (m) Column 2: y (m) Column 3: z (m) Column 4: SPL (dB re 1 Pa) Figures 5D-F and 5J-L contain 4 block matrices of 251 columns each in meshgrid format: Block matrix 1: x (m) Block matrix 2: y (m) Block matrix 3: z (m) Block matrix 4: SPL (dB re 1 Pa) Figures 6A-C and 6G-I data files contain the SPL re 1Pa at the vertices of the surface meshes of the 3 key anatomical groups (abdomen, spine, uterus). The field SPL is the same data as in the 2D plots. Column 1: x (m) Column 2: y (m) Column 3: z (m) Column 4: SPL (dB re 1 Pa) Figures 6D-F and 6J-L contain 4 block matrices of 251 columns each in meshgrid format: Block matrix 1: x (m) Block matrix 2: y (m) Block matrix 3: z (m) Block matrix 4: SPL (dB re 1 Pa) Figure 7A and 7B data Column 1: Frequency (Hz) Column 2: Low attenuation OptimUS solution (dB re 1 Pa) Column 3: High attenuation OptimUS solution (dB re 1 Pa) Column 4: Low attenuation analytical solution (dB re 1 Pa) Column 5: High attenuation analytical solution (dB re 1 Pa) Figure 7C-H Contains 4 block matrices of 250 columns each in meshgrid format Block matrix 1: x data (m) Block matrix 2: y data (m) Block matrix 3: z data (m) Block matrix 4: acoustic pressure magnitude data (Pa) Figures 8A and 8B Column 1: sample number Column 2: impulse response (re 1 Pa)
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
