Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Article . 2014
License: CC 0
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Article . 2014
License: CC 0
Data sources: ZENODO
versions View all 1 versions
addClaim

Blood Vessel Dihydroethidium (Dhe) Quantification Using Image J

Authors: sprotocols;

Blood Vessel Dihydroethidium (Dhe) Quantification Using Image J

Abstract

Author: Wei Ni I use Leica TCS SP5 Confocal Microscope for imaging, red channel for DHE signaling (pay attention to the special excitation and emission parameters) and green channel for collagen auto-fluorescence (I used the default setting for Alexa 488). Here is an example of DHE staining on mouse aorta. ![Figure 1](http://i.imgur.com/qorwSxO.jpg "Figure 1") ### Procedure 1. Open image in Image J. - Go to Image→Color→Split Channel. You will get three images in gray scale showing signals in red (image 1), green (image 2) or blue channel. I don’t have anything in blue channel, so just ignore the split result in blue channel. As you will see, I do have auto-fluorescent signal in the red channel, which was not showing obviously in the overlay. This is why I do not recommend only capture DHE signal and use the “measure” function, which will count both DHE signal and auto-fluorescent signal. (There is an exception. If you have super strong signal, you could use very low exposure time to avoid capturing the auto-fluorescent signal.) ![Figure 2](http://i.imgur.com/MQ22o9B.jpg "Figure 2") Image 1 ![Figure 3](http://i.imgur.com/hRPYLJl.jpg "Figure 3") Image 2 3.Go to Process→Image Calculator. Subtract the image green (image 2) from image red (image 1). 4.If the intensities of auto florescence are similar in these two channels, you will get rid off the auto fluorescence in red channel in the result (a new image will pop up, image 3). If you still have auto fluoresce in the result, just simply do the subtraction again. Make sure you do everything the same for images in all groups. ![Figure 4](http://i.imgur.com/QShwgGN.jpg "Figure 4") Image 3 5.Now we are ready to count the intensively of DHE signal. Click the result image (image 3), Go to Analyze → Measure, you will get integrated intensity for DHE signal. 6.You may notice, when you take images, the amount of blood vessel in each image may be different. For normalization, I count the area of auto fluorescence to represent the sample size in the image using image 2. Click image 2, go to Process→ Binary→ Make Binary (image 4). The binary step takes out the intensity variation of auto fluorescence in each image. Now, click image 4, Go to Analyze → Measure. Use the integrated intensity (represents area of auto fluorescence) for normalization. ![Figure 5](http://i.imgur.com/0wp4UQ1.jpg "Figure 5") Image 4 7.Calculate DHE signal / auto fluorescence signal ratio and compare each group.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 3
  • 3
    views
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
0
Average
Average
Average
3
Green