
Introduction: Sepsis is a potentially deadly medical condition characterized by a whole body inflammatory state due to a variety of pathogenic organisms in blood. Early diagnosis and initiation of proper antibiotic therapy by performing blood culture tests is of prime importance. Conventional blood culture method has some limitations, like prolonged time of reporting. Automated Blood Culture techniques for microbiological diagnosis of sepsis is more commonly used in comparison to conventional blood culture methods as it continuously monitors blood culture systems with faster turnaround time. This study was undertaken to evaluate the efficacy of the automated blood culture system of DG Technologies by comparing it with BacT/ALERT 3D 60. Material and Method: This study was conducted at department of microbiology, C U Shah Medical College, Surendranagar. Total seven organisms in different concentrations i.e 10, 102 and 104 CFU/ml were prepared and 1 ml suspension from each dilution was inoculated in aerobic blood culture bottles of both the manufacturers. Sterile whole blood in quantity of 5 ml was added in all the bottles to check the efficacy of blood culture media to neutralize the antimicrobial effect of the blood. Result: Both the system showed similar outcome for all seven organisms and for all three concentrations i.e 10, 102 and 104 CFU/ml. A minor difference in turnaround time was noted. The difference in time ranges from 10 to 30 min. Conclusion: The DG Technology automated blood culture system gives quite comparable results with the standard existing automated system (BacT/ALERT 3D 60).
Introduction: Sepsis is a potentially deadly medical condition characterized by a whole body inflammatory state due to a variety of pathogenic organisms in blood. Early diagnosis and initiation of proper antibiotic therapy by performing blood culture tests is of prime importance. Conventional blood culture method has some limitations, like prolonged time of reporting. Automated Blood Culture techniques for microbiological diagnosis of sepsis is more commonly used in comparison to conventional blood culture methods as it continuously monitors blood culture systems with faster turnaround time. This study was undertaken to evaluate the efficacy of the automated blood culture system of DG Technologies by comparing it with BacT/ALERT 3D 60. Material and Method: This study was conducted at department of microbiology, C U Shah Medical College, Surendranagar. Total seven organisms in different concentrations i.e 10, 102 and 104 CFU/ml were prepared and 1 ml suspension from each dilution was inoculated in aerobic blood culture bottles of both the manufacturers. Sterile whole blood in quantity of 5 ml was added in all the bottles to check the efficacy of blood culture media to neutralize the antimicrobial effect of the blood. Result: Both the system showed similar outcome for all seven organisms and for all three concentrations i.e 10, 102 and 104 CFU/ml. A minor difference in turnaround time was noted. The difference in time ranges from 10 to 30 min. Conclusion: The DG Technology automated blood culture system gives quite comparable results with the standard existing automated system (BacT/ALERT 3D 60).
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
