Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Conference object . 2018
License: CC BY
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Other literature type . 2018
License: CC BY
Data sources: ZENODO
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Conference object . 2018
License: CC BY
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
King's Research Portal
Contribution for newspaper or weekly magazine . 2018
License: CC BY
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 3 versions
addClaim

Predicting Clinical Deteriorations Using Wearable Sensors

Authors: Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Watkinson, Peter J; Clifton, David A; Beale, Richard; Alastruey, Jordi;

Predicting Clinical Deteriorations Using Wearable Sensors

Abstract

Introduction Acutely-ill hospitalised patients are at risk of clinical deteriorations such as cardiac arrest, admission to intensive care, or unexpected death. Currently, patients are manually assessed every 4-6 hours to determine the likelihood of subsequent deterioration. However, this is limited to intermittent assessments, delaying time-sensitive interventions. Wearable sensors, combined with an alerting system, could provide continuous automated assessments of the likelihood of deteriorations. To be suitable for hospital use, wearable sensors must be unobtrusive and provide reliable measurements of key vital signs including breathing rate (BR), a key predictor of deteriorations. The aims of this work were: (i) to develop a technique for monitoring BR unobtrusively using wearable sensors, and (ii) to assess whether wearable sensors provide reliable predictions of deteriorations when using this technique. Monitoring breathing rate (BR) unobtrusively Current methods for monitoring BR using wearable sensors are obtrusive. An alternative approach is to estimate BR from electrocardiogram or pulse oximeter signals, which are already acquired by wearable sensors to monitor heart rate and blood oxygen levels. Both signals are subtly modulated by breathing, providing opportunity to use them to monitor BR. I assessed the performance of previously proposed signal processing techniques for estimating BR from these signals in both healthy and hospitalised subjects. Although some techniques were precise enough for use with healthy subjects in the laboratory, they were imprecise when used with hospital patients. Therefore, I developed a novel technique, combining the strengths of time- and frequency-domain techniques. Its performance was assessed on data from 264 subjects. In hospital patients, the technique provided highly precise BRs 86% of the time, which exceeds the performance of manual observation, the current clinical standard. Assessing the reliability of wearable sensors for predicting deteriorations I implemented methods for rejecting unreliable sensor data, and for fusing continuous multiparametric data, to predict deteriorations. These were used alongside the novel technique for monitoring BR to predict deteriorations using wearable sensors. The system was assessed in a clinical trial of 184 hospital patients, conducted in collaboration with clinicians. The reliability of the system was assessed by comparing its predictions against documented deteriorations. Its predictive value was similar to that of the routine manual assessments (AUROCs of 0.78 vs 0.79). Crucially it provided continuous assessment, potentially providing predictions of deteriorations hours earlier than routine practice. Conclusion This work has demonstrated the potential for wearable sensors to reliably and unobtrusively predict deteriorations, when coupled with a novel technique for monitoring BR. This could improve patient outcomes, and reduce costs. Further work should investigate which patients would benefit most from this technology, and whether it could reduce clinical workload. In the future the technology could potentially be used with consumer wearables to improve patient safety in the community, where clinical expertise is less readily available.

This poster was displayed at the STEM for Britain event, held in the Houses of Parliament (London, UK) on 12th March 2018.

Country
United Kingdom
Keywords

wearable sensors, biomedical signal processing, electrocardiogram, clinical deterioration

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 6
    download downloads 3
  • 6
    views
    3
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
6
3
Green