Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Article . 2023
License: CC BY
Data sources: ZENODO
ZENODO
Article . 2023
License: CC BY
Data sources: Datacite
ZENODO
Article . 2023
License: CC BY
Data sources: Datacite
versions View all 2 versions
addClaim

Comparative Study Between Plating and Titanium Elastic Nailing System in Mid-Clavicular Fractures

Authors: Vinod Chandrashekaran Nair; Satyam Jawa; Swaroop Solunke; Omkar Rohidas Shinde;

Comparative Study Between Plating and Titanium Elastic Nailing System in Mid-Clavicular Fractures

Abstract

Background: Fracture of the clavicle is one of the most common bony injuries. The clavicle lacks a medullary cavity and is late to heal. Hence, proper technique is mandatory to heal the fracture as soon as possible. Hence, it has become a challenge for orthopaedic surgeons. Method: Out of 30 patients with clavicle fractures, 15 were treated with TENS and 15 with plating. Routine blood examination (CBC), an ECG, radiological study was carried out, and general anaesthesia was given. Results: Mean blood loss, timing for surgery, and size of wound were quite low in the nailing technique as compared to the plating technique, and the p value was highly significant (p<0.00). Surgical complications were also the least common with nailing techniques. The rate of union was 100% in both techniques. The mean dash square rate in the 1st, 2nd, and 6th months was highly significant in nail technique (p<0.001). Conclusion: Both techniques have 100% union of fracture and are equally effective in treating displaced mid-clavicular fractures. But due to the fewest post-surgical complications, TENS is preferred over the plating technique.

Background: Fracture of the clavicle is one of the most common bony injuries. The clavicle lacks a medullary cavity and is late to heal. Hence, proper technique is mandatory to heal the fracture as soon as possible. Hence, it has become a challenge for orthopaedic surgeons. Method: Out of 30 patients with clavicle fractures, 15 were treated with TENS and 15 with plating. Routine blood examination (CBC), an ECG, radiological study was carried out, and general anaesthesia was given. Results: Mean blood loss, timing for surgery, and size of wound were quite low in the nailing technique as compared to the plating technique, and the p value was highly significant (p<0.00). Surgical complications were also the least common with nailing techniques. The rate of union was 100% in both techniques. The mean dash square rate in the 1st, 2nd, and 6th months was highly significant in nail technique (p<0.001). Conclusion: Both techniques have 100% union of fracture and are equally effective in treating displaced mid-clavicular fractures. But due to the fewest post-surgical complications, TENS is preferred over the plating technique.

Keywords

TENS-Titanium, elastic nailing system, Plating technique, Fluoroscopy, DASH score, Maharashtra

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Green