In the CCUS industry, flow meters are widely used to measure liquid CO2 flowrate for custody transfer, emissions requirements and process monitoring and control in the loading/unloading of ships and trucks. Flow meters require calibration to accurately measure the mass or volume flowrate in the pipeline. This report first summarizes the current state of the art in traceable liquid CO2 flow measurement, making use of existing datasets on calibration facilities, liquid CO2 flow meters, and their calibration (transferability). This is then followed by a description of conceptual designs of test facilities for calibration of liquid/dense/supercritical CO2 flow meters, including an overview of operational and accuracy requirements, followed by chapters on test facility estimated calibration uncertainty and operational considerations
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |