{"references": ["A. A. White and M. M. Panjabi, \"Clinical biomechanics of the spine\" ,\n2nd ed., Philadelphia,: Lippincott Williams & Wilkins, 1990, ch1.", "T. C. Keller and C. Colloca, \"A rigid body model of the dynamic\nposteroanterior motion response of the human lumber spine\" J. Manip.\nPhys. Therap., vol. 25, no. 8, pp. 485-496, Oct. 2002.", "S. V. Bjornsdottir and S.Kumar, \"Posterior spinal mobilization: state of\nthe art review and discussion\" Disability and Rehab.., vol. 19, pp. 39-46, 1997.", "J. Gregory and D. C. Leman, \"Biomechanical assessment of lumber\nspinal function How low back pain sufferers differ from normals. Implications for outcome measures research. Part I: Kinematic\nassessments of lumber function\" J. Manip. Phys. Therap., vol. 27, no. 1,\npp. 57-62, Jan. 2004.", "T. Ikegami et al., \"Intermittent visual feedback can boost motor learning\nof rhythmic movements: Evidence for error feedback beyond cycles\" J.\nNeuroscience, vol. 32, no. 2, pp. 653-657, Jan. 2012.", "F. B. Ensink et al., \"Lumber range of motion: Influence of time of day\nand individual factors measurements \", Spine, vol. 21, no. 11, pp1339-\n1343, Jun 1996.", "L. Nicholson et al., \"Stiffness properties of the human lumber spine: A\nlumped parameter model\" Clinical Biomech., vol. 16, pp. 285-292, 2001.", "E. F. Owens et al., \"The reliability of a posterior-to-anterior spinal\nstiffness measuring system in a population of patents with low back pain\" J.Manip.Phys Therap., vol. 30, no. 2, pp 116-123, 2007.", "J. Latimer et al., \"Evaluation f a new device for measuring responses to\nposteroanterior forces in a patient population, Part 1: Reliability testing\", Phys. Therapy, vol. 76, no. 2, pp 158-165, Feb. 1996."]}
The posteroanterior manipulation technique is usually include in the procedure of the lumbar spine to evaluate the intervertebral motion according to mechanical resistance. The mechanical device with visual feedback was proposed that allows one to analysis the lumbar segments mobility “in vivo" facilitating for the therapist to take its treatment evolution. The measuring system uses load cell and displacement sensor to estimate spine stiffness. In this work, the device was tested by 2 therapists, female, applying posteroanterior force techniques to 5 volunteers, female, with frequency of approximately 1.2-1.8 Hz. A test-retest procedure was used for 2 periods of day. The visual feedback results small variation of forces and cycle time during 6 cycles rhythmic application. The stiffness values showed good agreement between test-retest procedures when used same order of maximum forces.
visual feedback, intervertebral manipulation device, lumber spine stiffness, Biomechanics
visual feedback, intervertebral manipulation device, lumber spine stiffness, Biomechanics
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |