Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao ZENODOarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
ZENODO
Article . 2005
License: CC BY
Data sources: ZENODO
Clinical Chemistry and Laboratory Medicine (CCLM)
Article . 2005 . Peer-reviewed
Data sources: Crossref
versions View all 3 versions
addClaim

Evaluation of immunoassays for the measurement of insulin-like growth factor-I and procollagen type III peptide, indirect biomarkers of recombinant human growth hormone misuse in sport

Authors: Abellan, Rosario; Ventura, Rosa; Pichini, Simona; Pascual, Jose A; Pacifici, Roberta; Di Carlo, Simonetta; Bacosi, Antonella; +2 Authors

Evaluation of immunoassays for the measurement of insulin-like growth factor-I and procollagen type III peptide, indirect biomarkers of recombinant human growth hormone misuse in sport

Abstract

AbstractInsulin-like growth factor-I (IGF-I) and procollagen type III peptide (P-III-P) have been proposed as indirect biomarkers for the detection of the misuse of recombinant human growth hormone in sport. An extended intra- and inter-laboratory validation of commercially available immunoassays was carried out. For total IGF-I, two radioimmunoassay (RIA) kits (IGF-I/RIA1, Nichols Institute Diagnostics and IGF-I/RIA2, Mediagnost) and one enzyme-linked immunosorbent assay (ELISA) (R&D) were evaluated. For P-III-P, two RIA kits (P-III-P/RIA3, Cis-bioInternational and P-III-P/RIA4, Orion Diagnostica) were studied. The intra-laboratory precision and accuracy values for all IGF-I assays were better than 15%. The IGF-I/ELISA showed the lowest limit of quantification (LOQ) and its calibration curve covered the range of concentrations found in human serum samples. Higher agreement between laboratory results was obtained for IGF-I/ELISA and IGF-I/RIA1. Low inter-technique correlation was obtained for the three assays; the only comparable results were obtained between IGF-I/ELISA and IGF-I/RIA1. For P-III-P, intra-laboratory precision and accuracy values better than 15% were obtained for both assays in almost all cases. The calibration curve for P-III-P/RIA4 covered the range of concentrations of serum samples, while 30% of the values for P-III-P/RIA3 were below the calibration sample with the lowest concentration. Inter-laboratory correlation was also higher for P-III-P/RIA4. In summary, ELISA and RIA4 were the most suitable assays for measurement of IGF-I and P-III-P, respectively, in serum samples. However, the validation studies carried out show the need for harmonization of immunoassay parameters to improve the reproducibility and comparability of results between different laboratories and in different studies.

Keywords

Adult, Male, Adolescent, Radioimmunoassay, Recombinant human growth hormone biomarkers, Enzyme-Linked Immunosorbent Assay, Validation Studies as Topic, Confidence Intervals, Humans, Insulin-Like Growth Factor I, Cryopreservation, Doping in Sports, Immunoassay, Human Growth Hormone, Reproducibility of Results, Procollagen type III peptide, Middle Aged, Peptide Fragments, Recombinant Proteins, Growth Hormone, Female, Biomarkers, Procollagen

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    30
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
30
Average
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!