Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Audiology and Neurot...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Audiology and Neurotology
Article
License: CC BY NC ND
Data sources: Sygma
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Audiology and Neurotology
Article . 2020 . Peer-reviewed
License: CC BY NC ND
Data sources: Crossref
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Audiology and Neurotology
Article
License: CC BY NC ND
Data sources: UnpayWall
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Radboud Repository
Article . 2020
Data sources: Radboud Repository
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Article . 2020
License: CC BY
Data sources: ZENODO
Audiology and Neurotology
Article . 2020 . Peer-reviewed
versions View all 7 versions
addClaim

Hearing Aid Treatment for Patients with Mixed Hearing Loss. Part II: Speech Recognition in Comparison to Direct Acoustic Cochlear Stimulation

Authors: Wardenga, N.; Snik, A.F.M.; Snik, A.F.M.; Kludt, E.; Waldmann, B.; Lenarz, T.; Maier, H.;

Hearing Aid Treatment for Patients with Mixed Hearing Loss. Part II: Speech Recognition in Comparison to Direct Acoustic Cochlear Stimulation

Abstract

<b><i>Background:</i></b> The conventional therapy for severe mixed hearing loss is middle ear surgery combined with a power hearing aid. However, a substantial group of patients with severe mixed hearing loss cannot be treated adequately with today’s state-of-the-art (SOTA) power hearing aids, as predicted by the accompanying part I of this publication, where we compared the available maximum power output (MPO) and gain from technical specifications to requirements for optimum benefit using a common fitting rule. Here, we intended to validate the theoretical assumptions from part I experimentally in a mixed hearing loss cohort fitted with SOTA power hearing aids. Additionally, we compared the results with an implantable hearing device that circumvents the impaired middle ear, directly stimulating the cochlea, as this might be a better option. <b><i>Objectives:</i></b> Speech recognition outcomes obtained from patients with severe mixed hearing loss supplied acutely with a SOTA hearing aid were studied to validate the outcome predictions as described in part I. Further, the results obtained with hearing aids were compared to those in direct acoustic cochlear implant (DACI) users. <b><i>Materials and Methods:</i></b> Twenty patients (37 ears with mixed hearing loss) were provided and fitted with a SOTA power hearing aid. Before and after an acclimatization period of at least 4 weeks, word recognition scores (WRS) in quiet and in noise were studied, as well as the speech reception threshold in noise (SRT). The outcomes were compared retrospectively to a second group of 45 patients (47 ears) using the DACI device. Based on the severity of the mixed hearing loss and the available gain and MPO of the SOTA hearing aid, the hearing aid and DACI users were subdivided into groups with prediction of sufficient, partially insufficient, or very insufficient hearing aid performance. <b><i>Results:</i></b> The patients with predicted adequate SOTA hearing aid performance indeed showed the best WRS in quiet and in noise when compared to patients with predicted inferior outcomes. Insufficient hearing aid performance at one or more frequencies led to a gradual decrease in hearing aid benefit, validating the criteria used here and in the accompanying paper. All DACI patients showed outcomes at the same level as the adequate hearing aid performance group, being significantly better than those of the groups with inadequate hearing aid performance. Whereas WRS in quiet and noise were sensitive to insufficient gain or output, showing significant differences between the SOTA hearing aid and DACI groups, the SRT in noise was less sensitive. <b><i>Conclusions:</i></b> Limitations of outcomes in mixed hearing loss individuals due to insufficient hearing aid performance can be accurately predicted by applying a commonly used fitting rule and the 35-dB dynamic range rule on the hearing aid specifications. Evidently, when outcomes in patients with mixed hearing loss using the most powerful hearing aids are insufficient, bypassing the middle ear with a powerful active middle ear implant or direct acoustic implant can be a promising alternative treatment.

Country
Netherlands
Keywords

Adult, Aged, 80 and over, Male, Hearing Tests, Biophysics, Middle Aged, Young Adult, Cochlear Implants, Hearing Aids, Acoustic Stimulation, Hearing, Speech Perception, Humans, Female, Aged, Hearing Loss, Mixed Conductive-Sensorineural, Retrospective Studies

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    10
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
10
Top 10%
Average
Average
Green
hybrid