Downloads provided by UsageCounts
doi: 10.1063/1.2185149
We have developed a new method for measuring the value of breakdown voltage in air for electrode separations from 400nmto45μm. The electrodes used were thin film Au lines evaporated on sapphire. The resulting capacitors had an area of 80×80μm2. We demonstrate the ability to deduce the value of the separation of the plates by the value of the capacitance. The data acquired with this method do not agree with Paschen’s law for electrode separations below 10μm, as expected from previous experiments. Amongst the improvements of our method are the measurement of plate separation and the very small surface roughness (average of 6nm).
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 69 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 63 | |
| downloads | 42 |

Views provided by UsageCounts
Downloads provided by UsageCounts