pmid: 23294132
Summary This trial aimed to compare the maternal and neonatal effects of remifentanil given by patient‐controlled analgesia (PCA) or continuous infusion for labour analgesia. Patient controlled analgesia was administered using increasing stepwise boluses from 0.1 to 0.4 μg.kg −1 (0.1 μg.kg −1 increment, 2 min lockout, n = 30). Continuous infusion used rates from 0.05 to 0.2 μg.kg −1 .min −1 (0.05 μg.kg −1 .min −1 increment, n = 30). Dose increments were given on request. Women reported lowest pain scores (median ( IQR [range]) of 3 (2–4 [2–5]) for PCA and 4 (3–5.25 [3–7]) for continuous infusion (p = 0.004) at 60 min after the beginning of analgesia. The mean ( SD ) remifentanil umbilical vein/maternal artery ratio in the PCA and infusion groups were 0.74 (0.45) vs 0.70 (0.52), respectively (p = 0.776). The mean ( SD ) umbilical artery/umbilical vein ratios were 0.31 (0.12) vs 0.26 (0.07), respectively (p = 0.088). Maternal and neonatal adverse reactions of remifentanil were similar between the two groups. The total remifentanil consumption (median ( IQR [range]) during PCA administration was lower than continuous infusion, 1.34 (1.22–1.48 [0.89–1.69]) mg vs 1.49 (1.35–1.61 [1.12–1.70] mg; p = 0.011). The results suggest that remifentanil PCA provides better pain relief and similar placental transfer compared with continuous infusion.
Adult, Analysis of Variance, Analgesia, Patient-Controlled, Blood Pressure, Nausea, Analgesics, Opioid, Fetal Heart, Double-Blind Method, Piperidines, Heart Rate, Patient Satisfaction, Pregnancy, Bradycardia, Analgesia, Obstetrical, Humans, Female, Prospective Studies, Infusions, Intravenous, Maternal-Fetal Exchange, Pain Measurement
Adult, Analysis of Variance, Analgesia, Patient-Controlled, Blood Pressure, Nausea, Analgesics, Opioid, Fetal Heart, Double-Blind Method, Piperidines, Heart Rate, Patient Satisfaction, Pregnancy, Bradycardia, Analgesia, Obstetrical, Humans, Female, Prospective Studies, Infusions, Intravenous, Maternal-Fetal Exchange, Pain Measurement
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 38 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |