pmid: 31104698
Periodically rotated overlapping parallel lines with enhanced reconstruction-echo planar imaging (PROPELLER-EPI) is a promising technique for non-sedated functional imaging due to its unique advantage of motion correction. However, its multiple-blades sampling blood-oxygen-level dependent (BOLD) signal leads to low sampling rate and aliasing of higher frequency physiological signal components such as the cardiac pulsation.In this study, we use near infrared spectroscopy (NIRS) synchronized with pulse sequences of PROPELLER-EPI, utilizing the fact that the optical sensing speed is inherently high. NIRS measures changes of oxyhemoglobin and deoxyhemoglobin to identify the transient states of on-BOLD and off-BOLD, and then labels each blade by temporal co-registration. The labeled blades from multiple epochs of a functional experiment are then used for the k-space data combination and subsequent image reconstruction. An eigenfunction model is proposed for temporal co-registration and to quantify the temporal resolution of the hemodynamic response.The experiment of NIRS labeled PROPELLER-EPI was carried out with the optical sampling rate of 10 Hz and the magnetic pulses repetition time of 1000 ms, and the temporal resolution is 20 times better than that of the state-of-the-art sliding-window PROPELLER-EPI. We compared the functional imaging results against the conventional magnetic resonance echo planar imaging-measured activity and achieved an accuracy of 0.9.Using the synchronization of NIRS, the proposed imaging scheme provides an effective way to implement PROPELLER-EPI, which features motion free, high SNR, and enhanced spatial-temporal resolution.
Models, Statistical, Spectroscopy, Near-Infrared, Echo-Planar Imaging, Hemodynamics, Reproducibility of Results, Signal-To-Noise Ratio, Magnetic Resonance Imaging, Oxygen, Hemoglobins, Motion, Oxyhemoglobins, Image Processing, Computer-Assisted, Humans, Artifacts
Models, Statistical, Spectroscopy, Near-Infrared, Echo-Planar Imaging, Hemodynamics, Reproducibility of Results, Signal-To-Noise Ratio, Magnetic Resonance Imaging, Oxygen, Hemoglobins, Motion, Oxyhemoglobins, Image Processing, Computer-Assisted, Humans, Artifacts
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |