image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Archivio della Ricer...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
versions View all 3 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

New HPLC instrument performance evaluation in HbA1c determination and comparison with capillary electrophoresis

Authors: Khashoggi, H.; Pignalosa, S.; Russo, C.; Pieri, M.; Bernardini, S.;

New HPLC instrument performance evaluation in HbA1c determination and comparison with capillary electrophoresis

Abstract

Glycated hemoglobin (HbA1c) measurement provides the most important medium to long-term marker of time-averaged glycemic status. Its relationship to clinical outcome in diabetes has been convincingly demonstrated for both type 1 and type 2 diabetes. The main HbA1c measurement methods for clinical routine are as follows: ion-exchange chromatography; affinity chromatography, capillary electrophoresis, immunoassay and enzymatic methods. In this study, we evaluated the analytical performances of a new HPLC instrument (Tosoh HLC-723 G11 in the VAR mode) in HbA1c analysis and compared it with a capillary electrophoresis instrument (Sebia Capillarys 2 Flex Piercing). HbA1c analysis was performed in parallel by both methods for 250 samples randomly chosen from healthy and diabetic subjects at 'Tor Vergata' University Hospital of Rome. Tosoh HLC-723 G11 showed good reproducibility for 10 days both in quality controls and in samples analyzed (%CV < 2%). We found good linearity for HbA1c values ranging from 15 mmol/mol (3.5%) to 178 mmol/mol (18.5%), with a correlation coefficient R2 = 1. In a comparison between Tosoh HLC-723 G11 and Capillarys 2FP a good correlation (r = 0.99) was found; however, Tosoh HLC-723 G11 showed higher values in the low range of HbA1c and lower in the high range (Tosoh HLC-723 G11 = 4.3043 + 0.913 Capillarys 2FP; p < 0.001). Tosoh HLC-723 G11 showed good repeatability, reproducibility, accuracy and automated simplicity, and it seemed suitable for routine use in clinical chemistry laboratories.

Country
Italy
Related Organizations
Keywords

Glycated Hemoglobin, Settore BIO/12 - BIOCHIMICA CLINICA E BIOLOGIA MOLECOLARE CLINICA, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Hyperglycemia, Electrophoresis, Capillary, Humans, Reproducibility of Results, Biomarkers, Chromatography, High Pressure Liquid

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    2
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
2
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!