Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Multi-centre calibration of an adaptive thresholding method for PET-based delineation of tumour volumes in radiotherapy planning of lung cancer

Authors: Nestle, Ursula; Kremp, Stephanie; Hellwig, Dirk; Grgic, Aleksandar; Buchholz, Hans Georg; Mischke, W.; Gromoll, C.; +10 Authors

Multi-centre calibration of an adaptive thresholding method for PET-based delineation of tumour volumes in radiotherapy planning of lung cancer

Abstract

SummaryPurpose: To evaluate the calibration of an adaptive thresholding algorithm (contrastoriented algorithm) for FDG PET-based delineation of tumour volumes in eleven centres with respect to scanner types and image data processing by phantom measurements. Methods: A cylindrical phantom with spheres of different diameters was filled with FDG realizing different signal-to-background ratios and scanned using 5 Siemens Biograph PET/CT scanners, 5 Philips Gemini PET/CT scanners, and one Siemens ECAT-ART PET scanner. All scans were analysed by the contrast-oriented algorithm implemented in two different software packages. For each site, the threshold SUVs of all spheres best matching the known sphere volumes were determined. Calibration parameters a and b were calculated for each combination of scanner and image-analysis software package. In addition, “scanner-typespecific” calibration curves were determined from all values obtained for each combination of scanner type and software package. Both kinds of calibration curves were used for volume delineation of the spheres. Results: Only minor differences in calibration parameters were observed for scanners of the same type (Δa ≤ 4%, Δb ≤ 14%) provided that identical imaging protocols were used whereas significant differences were found comparing calibration parameters of the ART scanner with those of scanners of different type (Δa ≤ 60%, Δb ≤ 54%). After calibration, for all scanners investigated the calculated SUV thresholds for auto-contouring did not differ significantly (all p > 0.58). The resulting sphere volumes deviated by less than –7% to +8% from the true values. Conclusion: After multi-centre calibration the use of the contrast-oriented algorithm for FDG PET-based delineation of tumour volumes in the different centres using different scanner types and specific imaging protocols is feasible.

Country
Germany
Related Organizations
Keywords

Lung Neoplasms, Radiotherapy Planning, Computer-Assisted, Reproducibility of Results, Radiotherapy Dosage, Reference Standards, Sensitivity and Specificity, Equipment Failure Analysis, Germany, Positron-Emission Tomography, Calibration, Humans, Algorithms

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    27
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
27
Top 10%
Top 10%
Top 10%
Related to Research communities
Cancer Research
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!